8.2
Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Use a filter or disposal bag when extracting
hazardous materials!
► Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room, the air renewal rate L within the room
must be sufficient. The volume of air dis
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
x air renewal rate L
R
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
8.3
Extracting fluids
WARNING
Risk of injury
► Do not evacuate combustible liquids!
The HEPA filter element shall only be
used for extracting dry materials.
Before extracting fluids, remove the filter bag
(see chapter
9.1
"
9.1
a special wet filter.
The dust extractor stops automatically when
the maximum level is reached.
CAUTION
Escaping foam and fluids
► Switch off the machine immediately and
empty the dust container.
8.4
The antistatic system
Friction inside the extraction hose causes static
electricity to develop during extraction. Operat
ing personnel may receive unpleasant electric
shocks while working. The mobile dust extrac
tor is fitted with an antistatic system as stand
ard to discharge any static electricity that may
develop. However, always use the enclosed an
tistatic extraction hose.
). Observe all the rele
W
"). We recommend using
9
Filter
WARNING
Risk of injury
► During the following procedure, take care
not to raise dust more that is unavoidable.
Moisten the filter element with a water
spray before removing it.
9.1
Changing the filter bag (FIS-CT
26/36/48)
Inserting the filter bag [5]
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Insert a new filter bag (FIS-CT 26/36/48) in
the inlet port of the dust container and in
terlock it. Important: be aware that the
locking engages.
Make sure that the filter bag is not
pinched between the top and bottom
sections.
► Replace the top section [2-1] and close the
locking clips [2-2].
Removing the filter bag [6]
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Remove the filter bag.
► Dispose of the used filter bag in accordance
with statutory regulations.
► Replace the top section [2-1] and close the
locking clips [2-2].
9.2
Changing the disposal bag
Inserting the disposal bag [7]
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Insert a new disposal bag (ENS-CT26/36/48)
on the inlet nozzle of the container and lock
in position.
Important: The lateral openings on the dis
posal bag must be positioned inside the
container. Make sure that the bolt engages.
► Place the disposal bag over the edge of the
container.
Make sure that the contacts [10-2] are
free.
English
9