Temp Display; Timer Display; Error Code; Test / Action - Wolf WWD30-2 Manual

Hide thumbs Also See for WWD30-2:
Table of Contents

Advertisement

Electronic Control Info.
Field Service Mode Unique Keystrokes:
key press
Enter Diagnostics
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
TIMER
NOTE: A colon (:) signifies the need to add two zeros (0) to the time shown. (i.e. 1:60 = 16000)
ERROR CODE TROUBLESHOOTING GUIDE:

ERROR CODE

10
(Invalid Checksum Error)
20
(Thermistor Open)
30
(Thermistor Short)
40
(Element Sensing)
50
(Door Switch)
60
(Stuck Relay)
70
(Cable Open)
NOTE: After correcting problem, errors code must be cleared. To clear error codes logged, press and hold
"TIMER" up and down arrow keys for 5 seconds, while in Field Service Mode.
#814750 - Revision A - January, 2011
Warming Drawer WWD30-2

TEMP DISPLAY

rE (Sr if in showroom mode)
Err
Err
Err
Err
Err
Err
Con
(Control On Time) 1:60 = 16000 hr. (See note below)
ELE (Element On Time) 95:00 = 950000 hr. (See note below)
FAn (Fan On Time) 12:60 = 126000 hrs. use (See note below)
Dor (Drawer Open/Close) 1:60 = 16000 cycles (See note below)
119 (Current Temp)
Figure 3-19. Field Service Mode.
CAUSE
Incorrect checksum
Temperature >300ºF
Temperature <-30ºF
<5º change in temperature over 10
minutes of continuous call for heat.
Occurs only during preheat mode and
the door is closed.
Door switch closed when the keypad is
being operated or unit turned on.
Drawer temperature rises to 250ºF in
any mode/state.
Cable wires that activate element or
fan relays on power board are not
making connection.
3-12

TIMER DISPLAY

0018 (Meaning revision 1.8)
10
20
30
40
50
60
deg

TEST / ACTION

Replace Control Board
In FSM (Field Service Mode), view temper-
ature as view by thermistor. Verify wiring
ok to element. Replace Thermistor if ok.
In FSM (Field Service Mode), view temper-
ature as view by thermistor. Verify wiring
ok to element. Replace Thermistor if ok.
If unit outdoors and temperature below
freezing point, instruct on unit limitations.
Verify Thermal Cutout is not open.
Verify Element is not open.
Replace TCO or Element if open.
Check operation of Door Switch with Ohm
meter. Replace if defective.
See Answer Advisor: WWD30 Error
Code 60
Check connection of comm cable. Use
Figure 5-1 to check voltage and/or ohm
reading of cable. If open, replace.