Salus MD22S Instruction Manual

22mm in-line magnetic filter

Advertisement

Quick Links

22mm in-line Magnetic Filter
Model: MD22S
Instruction Manual
Head Office:
SALUS Controls
Units 8-10, Northfield Business
Park, Forge Way, Parkgate
Rotherham, S60 1SD
Email: sales@salus-tech.com
www.salus-controls.com
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right
to change specification, design and materials of products listed in this brochure without prior
notice.
Issued: July 2021
V007
The following instructions are designed to help the engineer to install
and maintain the Magnetic Filter safely and efficiently and should be
followed and adhered to at all times. Make sure there is a water-filling
pipeline behind the filter. During maintenance, check whether the lid
seals are worn or damaged. The best practice is to replace the lid seal at
each repair.
1. INTRODUCTION
The Magnetic Filter is specially designed for central heating systems. It can
remove almost all the harmful black suspended iron oxide particles accumulated
in the central heating system and protect the complete central heating system.
2. MOUNTING RECOMMENDATIONS
The filter can be installed in a variety of ways, for example: be installed at any
location on the main pipeline. However, it is recommended to be installed
after the last radiator and before the boiler on the primary return pipework for
maximum protection and efficiency.
Note: It is important to have adequate access for maintenance and
servicing when determining a suitable installation location.
Recommended installation location
Boiler
RETURN
Header Tank
Vent
Pipe
Pump
Boiler
RETURN
3. STRUCTURE INTRODUCTION
2
Combination/Sealed system
Figure 1
3
Open vented system
Figure 2
1
1
Air vent valve
2
Magnet bar
3
Drain valve
4
Inlet valve
5
Outlet valve
5
4

Advertisement

loading

Summary of Contents for Salus MD22S

  • Page 1 Pump SALUS Controls is a member of the Computime Group Air vent valve Maintaining a policy of continuous product development SALUS Controls plc reserve the right Figure 2 Boiler to change specification, design and materials of products listed in this brochure without prior Magnet bar notice.
  • Page 2 Note: It is recommended that the magnetic filter is installed and maintained by a competant and 4. INSTALLATION METHOD qualified person. Any queries arising from either installation or servicing, contact SALUS Controls at techsupport@salus-tech.com 1. Cut and remove the section of the pipe according to the product installation length;...