Edit Function [ E D : T: ] - Toshiba TOSVERT VF-A5 Instruction Manual

Option, parameter writer
Hide thumbs Also See for TOSVERT VF-A5:
Table of Contents

Advertisement

E6580719
3-5
Edit function
[
E
d : t:
1
With the edit function, the data in the inverter memory and in the Parameter Writer memories A to D
can be edited, such as to change the parameter setting value for single inverter units.
The edit function is set and monitored as explained below.
[Operation procedure and explanation of actions]
(To edit parameter ._.
L
in memory C)
Operation
LED display
Action
I
6
I v I
Select the edit function on the function name display
Ed
:
:::
screen.
I
ENTER
I
When the function is set to the edit function, the display
Ed
::::
-
:
.-.
._.
will change to the device name display state (no prefix
symbol).
Select the memory to be edited.
I
6
I v I
: .-. ._. - c
(In this example, select memory
C .)
I
ENTER
I
Set the memory to be edited.
C- G.-.u
The display changes parameter group display state.
I
6
Iv I
Select the parameter group.
G.-.:=
(In this example, set
G .-.:= .)
I
ENTER
I
Set the parameter group.
G.-.:= - :=
H
The display will change to the parameter name display
state.
I
6
Iv I
Select the parameter name.
FH-._.L
(In this example, set ._.
L .)
Set the parameter name.
I
ENTER
I
uL -
50.0
The display will change to the data display state.
I
6
I v I
5 .-. .-.
,-, .-. .-.
u.u -
a
u.u
Change the data.
Save the data. The parameter name and data will
I
ENTER
I
,-,
.-.
.-.
I
appear alternately.
wu.•_i - -
._. ._
The state will move to the parameter name display
state.
-tr
G .-
.d
E
will compare the data in the two memories, and will display only the parameters that
differ when the memory is edited. If there are no differing parameters,
G ,-
.d
E
will not be
created.
-tr
The Parameter Writer will automatically reset the inverter after editing the data only when the
inverter memory has been edited. Do not turn the inverter power
OFF
until the reset has been
completed.
-tr
If a user device name is input in the Parameter Writer memory using the environment function, the
user device name will appear instead of the device names
:=: ,
b ,
C
or
d .
-tr
If memory protection is set with the environment function, the Parameter Writer memories A to D
cannot be edited.
-tr
To return the function name (
E
d : ::: ,
etc.) from the parameter name display, press the
I
ESC
I
key.
-tr
When the memory protection function (refer to 3-5) is set, the parameter settings cannot be
changed. If changes are attempted,
P .- 0:::
will appear.
-9-

Advertisement

Table of Contents
loading

Table of Contents