Copy Function - Toshiba TOSVERT VF-A5 Instruction Manual

Option, parameter writer
Hide thumbs Also See for TOSVERT VF-A5:
Table of Contents

Advertisement

E6580719
3-3
Copy function [
C 0
P
'::t]
When the copy function is selected, data can be copied in a batch between the inverter memory and
two random memories of the Parameter Writer memories A to D.
The copy function is set and monitored as explained below.
[Operation procedure and explanation of actions]
(To copy (writer) the inverter data into memory A)
Operation
LED display
Action
I
~
I
v
I
Select the copy function on the function name display
COP':::
screen.
When the function is set to the copy function, the
I
ENTER
I
c
0 p '::: --+ : .-. '-'
display will change to the device name display state (no
prefix symbol).
I
~
I
v
I
Select and set the copy source memory.
: .-.
'-'
The display changes to the device name display state
I
ENTER
I
(prefix symbol
~
).
Select the data copy destination memory.
I
~
I
v
I
~
R
(In this example, the memory
R
is selected.)
~
R-+
0
Set the copy destination memory.
I
ENTER
I
The % lamp will light, and the data will be copied while
displaying the copy progress.
99--+
E
.-.d
When the copying is completed,
E .-.
d
will appear.
I
ENTER
I
The display will change to the function name display
E
.-.d-+
COP':::
state.
*
When selecting the function or memory, the display can be changed with either
~
(forward
order) or
~(reverse
order).
*
When copying (writing) data to the inverter, after copying the data, the Parameter Writer will
automatically reset the inverter. Do not turn OFF the inverter power until the reset is completed.
(The data will not be transmitted correctly.)
*
If a user device name is input in the Parameter Writer memory using the environment function, the
user device name will appear instead of the device names
R , b ,
C
or
d .
*
If memory protection is set with the environment function, the Parameter Writer memories A to D
cannot be set as the copy destination device. (They will not appear as the copy destination
devices.) The copy target will always be from the Parameter Writer memory to the inverter
memory.
*
When copying the parameters to the inverter with
C 0
P ':::,
the LED at the upper right of the
inverter LED display will light.
Do not use the inverter's operation panel while operating the Parameter Writer.