2: Description
2.6 Air inlet system, functional
description
1. Air inlet filter
2. Clamp
3. Inlet tube
Figure 2-7: Air inlet system—ST4, ST5, ST7
Refer to Figure 2-7 and Figure 2-8. The compressor inlet
system consists of a dry-type air filter and an air inlet
valve.
The poppet-type air inlet valve controls the compressor's
air intake volume. Refer to Full load mode—50 to
127 psig (3.4 to 8.8 bar) on page 15. The air inlet valve
also acts as a check valve to prevent reverse rotation
when the compressor is shut down.
18
ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual
4. Clamp
5. Compressor unit
88292018-236 R00
Subject to EAR, ECCN EAR99 and related export control restrictions.
1. Air inlet filter
2. Clamp
Figure 2-8: Air inlet system—ST11, ST15
WARNING
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in
1
exposed plant piping."
®
Sullube
should not be used with PVC piping
systems. It may affect the bond at cemented
joints. Certain other plastic materials may also
be affected.
1
Plastic Pipe Institute, Recommendation B, Adopted
January 19, 1972.
3. Inlet adaptor
4. Compressor unit

Hide quick links: