Error Messages; Power Supply Hardware Error Messages; Calibration Error Messages; System Error Messages - Agilent Technologies 664xA Programming Manual

Gpib dc power supplies
Hide thumbs Also See for 664xA:
Table of Contents

Advertisement

Error Messages

Power Supply Hardware Error Messages

Front panel error messages resulting from selftest errors or runtime failures are described in "Chapter 3 - Turn-On
Checkout" of the power supply Operating Guide.

Calibration Error Messages

Front panel error messages resulting from calibration errors are described in Appendix A of the power supply Operating
Guide.

System Error Messages

System error messages are obtained remotely with the SYST:ERR? query or by pressing the front panel
error number is the value placed in the error queue. SYST:ERR? returns the error number into a variable and combines the
number and the error message into a string. Table 5-1 lists the system errors that are associated with SCPI syntax errors and
with interface problems. Information inside the brackets is not part of the standard error message, but is included for
clarification. When system errors occur, the Standard Event Status register (see "Chapter 4 - Status Reporting") records
them as follows:
Bit Set
Error Code
5
-100 thru -199
-200 thru -299
4
Error
Number
-100
Command error [generic command error]
-101
Invalid character
-102
Syntax error [unrecognized command or data type]
-103
Invalid separator [illegal character encountered in place of separator]
-104
Data type error [e.g., "numeric or string expected, got block date"]
-105
GET not allowed [ <GET> inside a program message]
-108
Parameter not allowed [too many parameters]
-109
Missing parameter [too few parameters]
-112
Program mnemonic too long [maximum 12 characters]
-113
Undefined header [syntactical correct but not defined for this device]
-121
Invalid character in number [e.g. alpha in decimal data, etc.]
-123
Exponent too large [ numeric overflow; exponent magnitude >32000]
-124
Too many digits [number too long; more than 255 digits received]
-128
Numeric data not allowed [numeric data not accepted where positioned]
-131
Invalid suffix [unrecognized suffix, or suffix not appropriate]
-138
Suffix not allowed [numeric element does not allow suffixes]
Standard Event Status Register Error Bits
Error Type
Command
Execution
Table 5-1. Summary of System Error Messages
Error String [Description/Explanation/Examples]
Bit Set
Error Code
3
-300 thru -399
-400 thru -499
2
5
key. The
Error Type
Device-dependent
Query
Error Messages
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

665xa667xa668xa669xa

Table of Contents