U-Line 3000 Series User Manual & Service Manual page 14

18” clear ice machine (115v)
Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
8
Wiring Plug
Ground Terminal
Pump Assembly
INSTALLATION PROCEDURE
!
WARNING
To prevent accidental electrocution, make
certain that the floor surfaces surrounding the
unit are dry whenever power/electricity is
removed from, or applied to the unit.
1. Disconnect your unit from its electrical outlet/socket.
2. Using a screwdriver or 1/4" nut driver, remove the 9
screws from the back panel.
3. Remove the drain line/pipe from the storage bin drain
nipple. Save the clamp for pump installation.
!
CAUTION
To prevent damage to the pump, leave sufficient
space between leveling leg and pump.
Discharge Tube Connector
Drain Tube Connector
Vent Tube Connector
14
Note: Slide clamp on hose end before installing hose. Do
not tighten clamp until pump and hoses have been
installed.
4. Install the 3 hoses and hose clamps to the pump
assembly as shown below. Do not tighten clamps at
this time.
Discharge Tube
5. Remove the protective paper from the adhesive strip
and carefully set pump inside of unit.
6. Unplug jumper block from ice
machine wiring harness
(jumper block has a single
pink wire). Discard jumper
block.
7. Connect pump wiring plug
to the ice machine wiring
harness connector, where
the jumper block was
removed. The connector is
keyed and can only be
inserted one way.
u-line.com
Drain Tube
Vent Tube
Jumper
Block
Pump Wiring
Plug
Drain Pump 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

3018clr

Table of Contents