Carrier GEMINI 38APS025-065 Installation Instructions Manual page 5

Air-cooled condensing units with puron refrigerant
Hide thumbs Also See for GEMINI 38APS025-065:
Table of Contents

Advertisement

38AP UNIT SIZE
NOMINAL CAPACITY, 50/60 Hz (tons)
CIRCUIT
OPERATING WEIGHTS (lb)
Standard
With Low Sound Option
REFRIGERANT CHARGE (lb)
Total*
Circuit A/Circuit B
NITROGEN SHIPPING CHARGE
COMPRESSOR
hp (Qty) (CKT A/CKT B)
CAPACITY STEPS
Standard
Digital Option
CRANKCASE HEATER (W) (each compressor)
CONDENSER FANS
Standard
Quantity
RPM
Diameter (in.)
Total Watts (60 Hz)
Total Watts (50 Hz)
Low Noise
Quantity
RPM
Diameter (in.)
Total Watts (60 Hz)
Total Watts (50 Hz)
CONDENSER COIL
No. Coils per Circuit
sq ft
TEMPERATURE RELIEF
CONNECTIONS (in.) ODF (CKT A/CKT B)
Suction Line
Liquid Line
MAXIMUM HEIGHT FOR 3° F SUBCOOLING
(ft)†
CAPACITY PER CIRCUIT (%) (CKT A/CKT B)
MINIMUM UNIT CAPACITY (%)
Standard Compressor
Digital Compressor
LEGEND
MCHX —
Microchannel Heat Exchanger
ODF
Outside Diameter, Female
*Typical operating charge with 25 ft of interconnecting piping. Operating
charge is approximate for maximum system capacity. Unit is factory supplied
with nitrogen holding charge. Refrigerant charge for dual circuit units is the
total for both circuits.
†Maximum vertical separation between evaporator coil and condensing unit if
condensing unit is below the evaporator.
Table 1 — 38AP025-050 Unit Physical Data — English
025
21/25
Dual
Single
Dual
1095
1077
1258
1131
1113
1294
24
24
26
12/12
24/—
13/13
11 (1)/
13 (1)/
11 (2)
11 (1)
13 (1)
2
2
2
22
22
22
2
2
2
3300
3300
3300
1997
1997
1997
2
2
2
2750
2750
2750
1664
1664
1664
1
1
1
27.1
27.1
33.9
1
3
/
/ 1
3
/
1
5
/
1
3
/
/ 1
8
8
8
8
5
/
/
5
/
5
/
5
/
/
8
8
8
8
75
75
75
50/50
100
50/50
50
50
50
17
17
17
027
030
23/27
25/30
Single
Dual
Single
1240
1264
1246
1276
1300
1282
26
28
29
26/—
14/14
29/—
15 psig
15 (1)/
13 (2)
15 (2)
15 (1)
2
2
2
22
22
22
90 (60 Hz), 75 (50 Hz)
Propeller Type, Axial, Vertical Discharge
2
2
2
1140 (60 Hz), 950 (50 Hz)
30
3300
3300
3300
1997
1997
1997
Plastic Type, Axial, Vertical Discharge
2
2
2
850 (60 Hz), 700 (50 Hz)
30
2750
2750
2750
1664
1664
1664
MCHX Type
1
1
1
33.9
33.9
33.9
Fusible Plug on Liquid Lines of Each Circuit - 210 F
3
/
1
5
/
1
3
/
/ 1
3
/
1
5
/
8
8
8
8
8
5
/
5
/
5
/
/
5
/
7
/
8
8
8
8
8
75
75
75
100
50/50
100
50
50
50
17
17
17
3
040
050
33/40
42/50
Dual
Single
Dual
2094
1968
2120
2148
2022
2174
38
39
48
21/17
39/—
22/26
10 (2)/
11 (2)/
13 (3)
8.5 (2)
13 (2)
4
3
4
36
27
36
3
3
3
4200
4200
4200
2541
2541
2541
3
3
3
3500
3500
3500
2118
2118
2118
1
2
1
67.8
67.8
67.8
1
5
/
/ 1
5
/
2
1
/
1
5
/
/ 1
5
/
8
8
8
8
8
5
/
/
5
/
7
/
5
/
/
5
/
8
8
8
8
8
75
75
75
54/46
100
48/52
27
33
23
13
16
11
Single
1977
2031
48
48/—
15 (3)
3
27
3
4200
2541
3
3500
2118
2
67.8
2
1
/
8
7
/
8
75
100
33
16