Alcatel-Lucent 9764
Metro Cell Outdoor V1.0 B1 WCDMA 1W
Site Preparation
3MN-01702-0001-RJZZA
Issue 5 | June 2014
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements

Advertisement

loading

Summary of Contents for Alcatel-Lucent 9764

  • Page 1 Use pursuant to applicable agreements Title page Alcatel-Lucent 9764 Metro Cell Outdoor V1.0 B1 WCDMA 1W Site Preparation 3MN-01702-0001-RJZZA Issue 5 | June 2014 Alcatel-Lucent – Proprietary Use pursuant to applicable agreements...
  • Page 2 The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2014 Alcatel-Lucent. All rights reserved. Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.
  • Page 3 S afety statements Overview Purpose This chapter presents the safety information for the Alcatel-Lucent 9764 Metro Cell Outdoor V1.0 B1 WCDMA 1W product. General safety and residual risk The equipment has been developed in line with state-of-the-art technology and conforms with current national and international safety requirements.
  • Page 4 Consequences if protective measures fail Avoidance message Protective measures to take to avoid the hazard Identifier The reference ID of the safety statement (optional) ..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 5 Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a hazardous situation not related to personal injury..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 6 • Grounding and circuit continuity is vital for safe operation of the equipment. Never operate the equipment with grounding/bonding conductor disconnected. • Before servicing, disconnect power input to reduce the risk of energy hazards..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 7 Turn off and lock out the system power at the disconnect device before working on or servicing the equipment..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 8 Workers equipped with personal medical electronic devices, such as pacemakers and hearing aids, shall consult the manufacturer's instructions and consult their occupational health practitioner..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 9 Make sure after finishing your work that no tools, testing equipment, flashlights, etc., have been left in or on the equipment..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 10 The instructions, cautions and warnings found on these labels must be understood and observed by all personnel involved with the equipment installation and maintenance..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 11 B asic site preparation requirements Overview Purpose This chapter describes basic site requirements that should be in place before installation of the Alcatel-Lucent 9764 Metro Cell Outdoor. Contents Environmental requirements Site requirements Cable management and constraints Installation clearances ..............................................Alcatel-Lucent – Proprietary...
  • Page 12 3GPP TS 25.101 3GPP TS 25.104 3GPP TS 25.141 The Alcatel-Lucent 9764 Metro Cell Outdoor is CE certified and meets the basic requirements of Directive R&TTE 1999/5/EC on telecommunications terminal equipment, regarding electromagnetic interference, safety and health. The Alcatel-Lucent 9764 MCO is compliant with RoHS and WEEE.
  • Page 13 General Safety EN 60950-22 (including EN 60950-1). Environment The Alcatel-Lucent 9764 Metro Cell Outdoor is compliant with the following: • Directive 2011/65/EC (RoHS) • Administrative measure on the control of pollution caused by electronic information products, Directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE) Electromagnetic compatibility (EMC) Spurious emissions 3GPP TS 25.113 and EN 301 908-1:...
  • Page 14 80 MHz – 2700 MHz with 1 kHz AM electromagnetic modulation depth 80% field immunity Level 3V/m Electrical fast EN 61000-4-4 Level 2 (1kV) transient Surges EN 61000-4-5 Level 3 (2kV) ..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 15 The Alcatel-Lucent 9764 MCO is designed to be mounted on poles or walls in a central location within the public spaces. Clear or open areas (where structures, trees, or hills do not obstruct radio signals to and from the equipment) will provide better performance than closed or filled areas.
  • Page 16 Straight connectors Cable management constraints The Alcatel-Lucent 9764 Metro Cell Outdoor must be installed in locations where it can guarantee the cable access in accordance with the bending radius of the cable. The bending radius of the cables are:...
  • Page 17 Clearances mm Comment Outdoor (inches) Side(s) 400 mm (15.75 inch) To secure the 9764 MCO module onto the 9764 Metro Dock module. To change the shield cover and open the connection cover. 400 mm (15.75 inch) To aid natural air convection.
  • Page 18 Basic site preparation requirements Installation clearances ............................................................................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 19 Overview Purpose This chapter provides information on grounding and lightning protection requirements that need to be in place at the site prior to installation of the Alcatel-Lucent 9764 Metro Cell Outdoor. Contents Grounding and lightning protection Product grounding ..............................................
  • Page 20 • International Electrotechnical Commission's international standard, 60364 Grounding requirements The Alcatel-Lucent 9764 Metro Cell Outdoor can be susceptible to lightning surges due to its association with elevated installation locations. It is therefore imperative that the equipment and installation site be properly grounded to a reliable and effective grounding electrode system such that a low impedance path to earth is provided.
  • Page 21 Important! Where uncertainty exists around the reliability and/or effectiveness of the main grounding system contact Alcatel-Lucent Technical Support or the appropriate electrical inspection authority. In addition the following document can also be used as a general reference for installation site grounding requirements, Grounding and Lightning Protection Guidelines for Wireless System Cell Sites, 401-200-115.
  • Page 22 The ground cable can be connected directly to the 9764 Metro Dock via a single hole grounding lug or preferably a double hole grounding lug crimped onto the cable. M6 screws are used to attach the ground cable to the grounding point on the 9764 Metro Dock module.
  • Page 23 The following figure shows the grounding point on the 9764 MCO WCDMA module. The ground cable can be connected directly to the 9764 MCO module via a double hole grounding lug crimped onto the cable. M5 screws are used to attach the ground cable to the grounding point on the 9764 MCO module.
  • Page 24 Grounding and lightning protection requirements Product grounding ............................................................................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 25 E lectrical power requirements Overview Purpose This chapter provides information relating to the site preparation power requirements prior to installation of the Alcatel-Lucent 9764 Metro Cell Outdoor V1.0 B1 WCDMA Contents Site power requirements (AC) Product power requirements ..............................................Alcatel-Lucent – Proprietary...
  • Page 26 Site power requirements (AC) Purpose This section describes the power and grounding requirements that must be considered when planning site facilities for Alcatel-Lucent installed equipment and products. General requirements All power and grounding system wiring, short-circuit (over-current) protection and surge protection devices must be installed by the appropriately licensed personnel.
  • Page 27 Das am Standort installierte Gerät muss über die Wechselstromversorgung des Kunden mit Strom versorgt werden. Der Wechselstrom-Anschlusspunkt muss für das Serviceteam leicht zugänglich und als Freischalteinrichtung für das Gerät ausgewiesen sein..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 28 CAT III or CAT IV Spannungsstoßschutz Im Lieferumfang des Produkts ist kein Überspannungsschutzgerät enthalten. Dieses muss vom Kunden bestellt und im Zuge der Standortvorbereitung installiert werden..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 29 As part of site preparation, the customer must provide the metal conduit and associated fittings for cable routes and connecting conduit to the outdoor equipment..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 30 Electrical power requirements Product power requirements ..............................................Product power requirements Product power data The following table provides power related information applicable to the Alcatel-Lucent 9764 Metro Cell Outdoor V1.0 B1 WCDMA 1W Power supply Power mode AC power variant only...
  • Page 31 Power connector AC power connector Power connection point Power is supplied to the 9764 MCO module and the 9764 Metro Dock module via an AC connector on the reverse side of the 9764 MCO module. 9764 MCO B1 module (reverse view)
  • Page 32 Electrical power requirements Product power requirements ............................................................................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 33 B ackhaul requirements Overview Purpose This chapter provides the backhaul requirements for the Alcatel-Lucent 9764 Metro Cell Outdoor site. Contents Ethernet requirements ..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 34 Copper LAN cable (CAT 5E or higher) SFP transceivers The Alcatel-Lucent 9764 Metro Dock supports the backhaul function in the form of 2 GE ports for optical/electrical SFP transceivers. One for backhaul (BH1) and one for daisy-chaining (BH2) to a second Alcatel-Lucent 9764 MCO.
  • Page 35 Where electrical backhaul is used (1000 BaseT) it is highly recommended to use an optional Ethernet surge arrestor as the GBE ports within the Alcatel-Lucent 9764 Metro Dock provide no surge protection for the backhaul connection. Two different types of Ethernet surge arrestor are available.
  • Page 36 – +/- 48V DC (nominal) – +/- 60V DC (max. continuous) • Maximum surge: – 100A, 10/1000µsec CORE-1089 – 3kA, 8/20 µsec IEC 61000-4-5 ..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO Use pursuant to applicable agreements 3MN-01702-0001-RJZZA Issue 5 June 2014...
  • Page 37 As part of site preparation, the customer must provide the metal conduit and associated fittings for cable routes and connecting conduit to the outdoor equipment..............................................Alcatel-Lucent – Proprietary Alcatel-Lucent 9764 MCO 3MN-01702-0001-RJZZA Use pursuant to applicable agreements Issue 5 June 2014...
  • Page 38 Packing List, immediately notify the carrier that delivered the unit and contact your Alcatel-Lucent representative. The Alcatel-Lucent 9764 Metro Dock product packaging contains the following items: • The 9764 Metro Dock module (including lock and key)
  • Page 39 Installation of the 9764 Metro Dock 9764 Metro Dock Pre-installation information 9764 Metro Dock pre-installation ..............................................Tools required for installation The following tools may be used during installation: • Drill (pneumatic hammer) and assorted drill bits • Pliers • Adjustable spanners •...
  • Page 40 Pole mount options The 9764 Metro Dock is less than 1 kg (2.2 lbs) and can be easily mounted onto a pole (wooden or metal) for the following installation options: • 9764 Metro Dock screwed onto a wooden pole (without the tilt option).
  • Page 41 Installation of the 9764 Metro Dock Pole mount installation requirements 9764 Metro Dock pre-installation ..............................................Figure 7-1 Pole mount banding and brackets Standard pole Tilt bracket bands and buckle assembly Recommended pole anchor materials Surface structure Recommended anchor materials Recommended screw torque...
  • Page 42 9764 Metro Dock pre-installation ..............................................Pole mount installation examples The following figures show examples of 9764 Metro Dock pole mount installation or pole mount installation using vertical tilt. Figure 7-2 9764 Metro Dock pole mount using screws Pole mount - without tilt...
  • Page 43 Wall mount options The 9764 Metro Dock weighs less than 1 kg (2.2 lbs) and can be easily mounted onto any flat, sturdy wall for the following installation options: • 9764 Metro Dock attached directly onto a wall or flat surface (using wall spacer) •...
  • Page 44 Washer plain M6x12x1.6mm stainless steel (x3) Washer spring M6x12x1.2mm stainless steel (x3) Plug expansion Rawlnut M6x50 (x3) Wall mount installation examples The following figures show examples of 9764 Metro Dock wall mount installation and wall mount installation with horizontal/vertical tilt..............................................Alcatel-Lucent – Proprietary...
  • Page 45 Installation of the 9764 Metro Dock Wall mount installation requirements 9764 Metro Dock pre-installation ..............................................Figure 7-5 9764 Metro Dock wall mount (no tilt) Figure 7-6 9764 Metro Dock wall mount (with tilt) Horizontal/Vertical tilt Vertical tilt only Horizontal tilt only combination ..............................................
  • Page 46 Metro Dock onto a pole or wall with or without the optional tilt mechanism. Contents Procedure 7-1: Pole mount the 9764 Metro Dock 7-14 Procedure 7-2: Pole mount the 9764 Metro Dock using optional tilt brackets 7-20 Procedure 7-3: Wall mount the 9764 Metro Dock 7-30...
  • Page 47: Procedure 7-1: Pole Mount The 9764 Metro Dock

    Before mounting the 9764 Metro Dock: • Record the 9764 Metro Dock 18 digit serial number • On the 9764 Metro Dock ensure that the Metro Dock spacer is not attached. If the spacer is present remove it by unscrewing the M5 screw: ..............................................
  • Page 48 Installation of the 9764 Metro Dock Procedure 7-1: Pole mount the 9764 Metro Dock 9764 Metro Dock installation ..............................................M5x12 countersunk screw Metro Dock Metro Dock spacer removed spacer Before you begin Before you begin this procedure, the following should be observed.
  • Page 49 Perform the following procedure to mount the 9764 Metro Dock onto a wooden pole using bolts........................................Measure the height at which the 9764 Metro Dock is to be positioned on the pole. Mark this point........................................Using a digital compass determine the planned horizontal (left/right) orientation of the 9764 Metro Dock around the pole.
  • Page 50 Perform the following procedure to mount the 9764 Metro Dock onto a pole (wooden or metal) using standard pole bands........................................Measure the height at which the 9764 Metro Dock is to be positioned on the pole. Mark this point........................................
  • Page 51 Tip: Use an adjustable strap, cable ties or heavy duty duct tape to temporarily hold the 9764 Metro Dock against the pole while the lower band is applied........................................Taking the other steel band, place the band around the lower lug on the 9764 Metro Dock and the pole. Metro Dock...
  • Page 52 9764 Metro Dock installation ....................................................................................... Finally, check the banding is secure, there is no movement of the 9764 Metro Dock around the pole and that the banding stubs (cut ends) are flattened down with a hammer. S T E P S ........................................
  • Page 53 • the appropriate mounting hardware and any necessary supporting material is used. Mounting requirements and materials The 9764 Metro Dock can be mounted onto a wooden or metal pole. Refer to the following for the installation kits, anchor materials and tools for the installation type: •...
  • Page 54 Bracket pole mount using bolts Perform the following procedure attach the vertical tilt bracket a wooden pole using bolts........................................Measure the height at which the 9764 Metro Dock is to be positioned on the pole. Mark this point........................................
  • Page 55 Tip: Use an adjustable strap, cable ties or heavy duty duct tape to temporarily hold the 9764 Metro Dock against the pole while the bolts are applied........................................
  • Page 56 Perform the following procedure to mount the vertical tilt bracket onto a pole (wooden or metal) using standard pole bands........................................Measure the height at which the 9764 Metro Dock is to be positioned on the pole. Mark this point........................................
  • Page 57 At the marked installation position on the pole wrap the upper and lower pole bands around the pole at the determined height. Carry out any required adjustment of the 9764 Metro Dock around the pole so that it is pointing in the planned direction.
  • Page 58 Procedure 7-2: Pole mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ....................................................................................... Once the 9764 Metro Dock is in the correct position and orientation tighten and secure the bands around the pole. Refer to BAND-IT ® C00169 Hand Tool Operation Instructions, PO5886.
  • Page 59 Lower M6 bolt x 1 ........................................Position the 9764 Metro Dock against the front of the tilt bracket so that the two upper bolt holes and the single lower bolt hole on the 9764 Metro Dock are aligned with the bolts holes on the tilt bracket.
  • Page 60 Metro Dock (the chamfered midsection of the elongated hole is used for banding installation)........................................Move the 9764 Metro Dock metal slider to the “up” position as this allows easier access to the lower attachment bolt hole: 1. insert supplied key into lock 2.
  • Page 61 ....................................................................................... From the 9764 Metro Dock side, screw in t the single M6 bolts through the lower bolt hole on the 9764 Metro Dock and into the lower tilt bracket bolt hole. Lower Metro Dock attachment bolt ........................................
  • Page 62 Metro Dock mounted on wooden pole with vertical tilt metal pole with vertical tilt How to continue After mounting the 9764 Metro Dock onto a pole the cables need to be connected. Continue with the, “9764 Metro Dock cabling” (p. 7-50) section.
  • Page 63: Procedure 7-3: Wall Mount The 9764 Metro Dock

    Mounting requirements and materials The 9764 Metro Dock is less than 1 kg (2.2 lbs) and can be easily mounted onto solid concrete or wooden flat surface. Refer to the following for the installation kits, anchor materials and tools for the installation type: •...
  • Page 64 Installation of the 9764 Metro Dock Procedure 7-3: Wall mount the 9764 Metro Dock 9764 Metro Dock installation ..............................................M5x12 countersunk screw Metro Dock Metro Dock spacer removed spacer Before you begin Before you begin this procedure, the following should be observed.
  • Page 65 Perform standard wall mount installation Perform the following procedure to mount the 9764 Metro Dock directly onto a wall........................................Measure the height at which the 9764 Metro Dock is to be positioned on the wall. Mark this point........................................
  • Page 66 Surface structure is wood Proceed with the next step........................................Move the 9764 Metro Dock metal slider to the “up” position as this allows easier access to the lower attachment bolt hole: 1. insert supplied key into lock 2. turn the key to its hard stop position to unlock the slider 3.
  • Page 67 Screw in the upper and lower bolts into the drilled anchor holes for a concrete surface, or directly into the wooden surface, to the appropriate depth so that the wall spacer and 9764 Metro Dock are securely attached to the wall.
  • Page 68 Standard wall mount example The following figure depicts a standard wall mount. How to continue After mounting the 9764 Metro Dock onto a pole, the cables need to be connected. Continue with the, “9764 Metro Dock cabling” (p. 7-50) section.
  • Page 69 Mounting requirements and materials The 9764 Metro Dock is less than 1 kg (2.2 lbs) and can be easily mounted onto solid concrete or wooden flat surface. Refer to the following for the installation kits, anchor materials and tools for the installation type: •...
  • Page 70 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ..............................................Before you begin Before you begin this procedure, the following should be observed. WARNING Fall hazard Falls can occur when working at heights resulting in serious personal injury or death.
  • Page 71 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ..............................................52 mm (2.05 inches) Tip: If the tilt bracket is available it can be placed against the wall and be used as a template to mark the points on the wall for the bracket anchor holes.
  • Page 72 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ....................................................................................... Once the mounting surface has been prepared the tilt brackets can be attached. Continue with one of the following procedures depending on the tilt configuration: If..
  • Page 73 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ....................................................................................... Depending on the required vertical tilt orientation ensure the bracket is positioned the correct way up before placing on the wall: If...
  • Page 74 9764 Metro Dock installation optional tilt brackets ....................................................................................... Once the tilt bracket is mounted the 9764 Metro Dock can be attached. Continue with “Attach 9764 Metro Dock to the tilt bracket” (p. 7-25). S T E P S ........................................
  • Page 75 Recommended screw torque; 7.0 N.m (62.0 lb.in)........................................Once the tilt bracket is mounted the 9764 Metro Dock can be attached. Continue with “Attach 9764 Metro Dock to the tilt bracket” (p. 7-25).
  • Page 76 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ..............................................Mount combined horizontal/vertical tilt brackets Perform the following procedure to attach the combined horizontal/vertical tilt bracket onto a flat surface or wall.
  • Page 77 Installation of the 9764 Metro Dock Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ..............................................If... Then... View... right horizontal tilt and the brackets should be attached with downward vertical tilt is...
  • Page 78 Recommended screw torque; 7.0 N.m (62.0 lb.in)........................................Once the tilt bracket is mounted the 9764 Metro Dock can be attached. Continue with “Attach 9764 Metro Dock to the tilt bracket” (p. 7-25).
  • Page 79 Lower M6 bolt x 1 ........................................Position the 9764 Metro Dock against the front of the tilt bracket so that the two upper bolt holes and the single lower bolt hole on the 9764 Metro Dock are aligned with the bolts holes on the tilt bracket.
  • Page 80 Metro Dock (the chamfered midsection of the elongated hole is used for banding installation)........................................Move the 9764 Metro Dock metal slider to the “up” position as this allows easier access to the lower attachment bolt hole: 1. insert supplied key into lock 2.
  • Page 81 ....................................................................................... From the 9764 Metro Dock side, screw in t the single M6 bolts through the lower bolt hole on the 9764 Metro Dock and into the lower tilt bracket bolt hole. Lower Metro Dock attachment bolt ........................................
  • Page 82 Procedure 7-4: Wall mount the 9764 Metro Dock using 9764 Metro Dock installation optional tilt brackets ..............................................How to continue After mounting the 9764 Metro Dock onto a pole, the cables need to be connected. Continue with the, “9764 Metro Dock cabling” (p. 7-50) section..............................................
  • Page 83: Overview

    Contents Procedure 7-5: 9764 Metro Dock ground cabling 7-51 Procedure 7-6: 9764 Metro Dock-Erdungsverkabelung 7-53 Procedure 7-7: 9764 Metro Dock Ethernet cabling - Fiber optic 7-55 Procedure 7-8: 9764 Metro Dock Ethernet cabling - Electrical 7-62 ..............................................Alcatel-Lucent – Proprietary...
  • Page 84: Procedure 7-5: 9764 Metro Dock Ground Cabling

    Route the ground cable from the site grounding system to the 9764 Metro Dock........................................At the 9764 Metro Dock cut the ground cable to a proper length and strip the cable end to expose approximately 20 mm (0.75 in).
  • Page 85 ........................................Place one washer (wave spring washer) on each terminal screw, align the grounding cable lug holes with the earthing terminal holes on the 9764 Metro Dock, and secure the cable to the grounding point using the terminal screws. Bottom view...
  • Page 86: Procedure 7-6: 9764 Metro Dock-Erdungsverkabelung

    Führen Sie das Erdungskabel vom Erdungssystem des Standorts zum 9764 Metro Dock........................................Schneiden Sie das Erdungskabel am 9764 Metro Dock in einer geeigneten Länge ab, und streifen Sie den Kabelmantel am Kabelende ab, um ca. 20 mm (0,75 Zoll) des Kabels freizulegen.
  • Page 87 9764 Metro Dock cabling ....................................................................................... Reinigen Sie die Kontaktfläche des Kabelschuhs und des Erdungspunktes am 9764 Metro Dock, und verwenden Sie ein Antioxidationsmittel, um ein Oxidieren zu verhindern........................................Platzieren Sie einen Dichtungsring (Federring) auf den Anschlussschrauben, richten Sie die Löcher des Kabelschuhs am Erdungskabel an den Anschlusslöchern des 9764 Metro...
  • Page 88: Procedure 7-7: 9764 Metro Dock Ethernet Cabling - Fiber Optic

    Ethernet: • SFP GBE 1000Base/CPRI SFP module (SM or MM). See “SFP modules” (p. 2-11). • Fiber Optic Ethernet cable with LC connector to optical SFP module at the 9764 Metro Dock module. See “Ethernet cable - Optical” (p. 2-12).
  • Page 89 2. Momentarily touch the ESD clip onto a bare (unpainted) metal spot so that any built up static charge is dissipated. 3. Attach the ESD clip to the 9764 Metro Dock ground lug screw (the ground lug screw can be unscrewed slightly for easier ESD clip attachment).
  • Page 90 ESD ground strap ........................................In order to remove the 9764 Metro Dock protective plate, ensure the Metro Dock metal slider is in the default “down” position. This allows easier access to all six of the plate retention screws.