Service Parts Information; Service Parts Information 1 : Compressor; Service Parts Information 2 : Inverter Compressor - Fujitsu Waterstage Comfort Series Maintenance Document

Air to water heat pump, refrigerant r410a inverter, outdoor/hydraulic unit
Table of Contents

Advertisement

Split system single phase type
2 4

Service parts information

2 4 1 Service parts information 1 : Compressor

Service parts information 1 : Compressor
Diagnosis method of compressor (if outdoor unit LED displays error, refer to Failures and clears)
Does not start up
Is there open or loose
connection cable?
Check connection of
compressor, and winding
resistance (Refer to the next
page).
If there is no failure, the
defected of compressor is
considered (locked
compressor due to clogged
dirt or less oil).
Replace compressor

2 4 2 Service parts information 2 : Inverter compressor

Check point 1 : Check connection
Check terminal connection of compressor
(Loose or incorrect wiring)
(WHITE)
Transistor PCB (IPM)
(RED)
Maintenance document "1792 - EN"
Stops soon after starting up
Is there open or loose
connection cable?
Is gas pipe valve open ?
(Low pressure is too low)
Check if refrigerant is leakin.
Recharge refrigerant.
Check if stainer is clogged
(Parts information 3)
Check inverter PCB, connection of compressor, and
winding resistance (refer to the next page).
If there is no failure, the defected of compressor is
considered (Compression part broken or valve
defective).
Replace compressor
Only for WO*A080LFCA, WO*A100LFTA :
Check connection of transistor PCB (IPM)
(Loose or incorrect wiring)
(BLACK)
Check if vibration noise by
loose bolt or contact noise of
piping is happening.
Defective compressor can
be considered (due to inside
dirt clogging or broken
component).
Replace compressor
WOYA080LFCA, WOYA100LFTA :
Transistor PCB (IPM)
RED
Compressor
Abnormal noise
BLACK
WHITE
- 33 -

Advertisement

Table of Contents
loading