Connectors For The Power Supply Of The Scalance W786 - Siemens SCALANCE W786-1PRO Operating Instructions Manual

Industrial wireless lan outdoor access point
Hide thumbs Also See for SCALANCE W786-1PRO:
Table of Contents

Advertisement

Figure 6-3
6.4

Connectors for the power supply of the SCALANCE W786

Possible power supplies
The following power supplies are suitable for the SCALANCE W786:
● 48 VDC direct voltage
● 12 - 24 VDC direct voltage
● 100 - 240 VDC direct voltage
● Power over Ethernet (PoE, only with the RJ-45 variants)
SCALANCE W786 outdoor access point
Operating Instructions, 06/2013, A5E02280428-08
View from above with an FO cable inserted in the strain relief clamp
Use the two-pin connector supplied with the SCALANCE W786.
Use the power supply adapter 12 - 24 VDC available as an accessory.
Use the power supply adapter 100 - 240 VDC available as an accessory.
If an eight-wire Ethernet cable is used, it is possible to supply power over the four wires
that are not used as data lines. As an alternative, the voltage can be modulated onto the
data lines ("phantom power").
If a Fast Connect Ethernet connector is used to allow cable assembly in the field and due
to its greater mechanical strength, you can only use four-wire cables. In this case, only
phantom power is possible. This does not represent a restriction for the user because
PoE-compatible power equipment always provides both options.
6.4 Connectors for the power supply of the SCALANCE W786
Connecting up
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w786-2proScalance w786-3proScalance w786-2rr

Table of Contents