Oregon Scientific BAR913HG User Manual

Oregon Scientific BAR913HG User Manual

Digital weather forecaster with in-out thermohygrometer and rf clock

Advertisement

Quick Links

DIGITAL WEATHER FORECASTER
WITH IN-OUT THERMO-
HYGROMETER AND RF CLOCK
MODEL : BAR913HG
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the BAR913HG Digital
Weather Forecaster with In-Out Thermo-Hygrometer and RF Clock.
The BAR913HG is an all-in-one weather forecasting device and
clock.
The BAR913HG, a weather forecasting device, has several weather
related functions. A main feature is that it takes and records
temperatures and humidities in more than one location. Using a
wireless remote thermo-hygro sensor, it can simultaneously monitor
temperatures and humidities in three remote locations. The unit
will show temperature and humidity trends as well as record
maximum and minimum temperature and humidity readings.
BAR913HG is able to receive and display readings from up to 3
remote sensors.
As part of the weather forecasting function, the unit has a built-in
barometer that displays atmospheric pressure. Using kinetic-
movement graphic illustrations the unit displays atmospheric
pressure trends and displays forecasts as sunny, partly cloudy,
cloudy, rainy and snowy.
The BAR913HG is also a Radio Frequency (RF) controlled clock. It
can automatically synchronize its current time and date when it is
913hg-e.p65
1
brought within an approximate 1500 km radius of the radio signal
DCF77 generated from Frankfurt, Germany.
Other features of the BAR913HG include backlight, extra-large
liquid crystal display (LCD) and a daily crescendo alarm with an
eight minute snooze function.
No wire installation is required between the main and remote units
as the BAR913HG operates at 433 MHz, it can be used in the USA
and most places in Continental Europe.
MAIN FEATURES: MAIN UNIT
1
07/12/2001, 3:06 PM

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific BAR913HG

  • Page 1 MODEL : BAR913HG No wire installation is required between the main and remote units as the BAR913HG operates at 433 MHz, it can be used in the USA USER’S MANUAL and most places in Continental Europe.
  • Page 2 FRONT DISPLAY CONTROL BUTTONS The LCD is divided into five easy-to-read sections. Each CHANNEL CHANNEL CHANNEL CHANNEL] BUTTON B1. [CHANNEL section has a specific purpose that relates to weather Displays the temperature and humidity readings of the indoor forecasting, temperature, humidity, pressure and clock / or remote sensor calendar / alarm functions.
  • Page 3: Features: Remote Thermo-Hygro Sensor

    BACK PANEL FEATURES: REMOTE THERMO-HYGRO SENSOR C1. BATTERY COMPARTMENT Accommodates four UM-3 or “AA” size alkaline batteries C2. mb / hPa - inHg SLIDE SWITCH Selects between "mb / hPa" or "inHg" pressure unit display C3. RESET SLOT Resets the unit by returning all setting to their default values C4.
  • Page 4: Battery Installation: Main Unit

    TWO-LINE LCD BATTERY INSTALLATION: MAIN UNIT Displays the current temperature and humidity monitored by the remote unit 1. Gently lift the tab on the battery compartment door. LED INDICATOR 2. Insert four UM-3 or “AA” size alkaline batteries. Flashes when the remote unit transmits a reading °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) CHANNEL SLIDE SWITCH...
  • Page 5: About Radio Reception

    The BAR913HG is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal. When the BAR913HG is within range, its radio-control mechanism will override all manual settings. 913hg-e.p65 07/12/2001, 3:06 PM...
  • Page 6: How To Manually Set The Clock

    HOW TO MANUALLY SET THE CLOCK Press MODE and hold for three seconds. The 12-hr value will flash. Use the UP(+) or DOWN(-) buttons to make a selection between a German twenty-four hour display and a twelve hour display. Press MODE again, the hour will flash. Use the UP(+) or DOWN (-) button to enter the hours.
  • Page 7: Alarm And Snooze Function

    To disable this function, press the DOWN button in the Pre-Alarm ALARM AND SNOOZE FUNCTION mode. The [ ] symbol will disappear and "-:--" will appear to indicate disable of this function. When the daily alarm goes off alarm, the backlight will be on for five seconds and the ALARM ON icon will flash.
  • Page 8: Note On Remote Readings

    To activate this function, press and hold the CHANNEL button for MAXIMUM AND MINIMUM 3 seconds. To deactivate press the CHANNEL button again. TEMPERATURES & HUMIDITIES If the reading goes above or below the specified amounts, the display will show a flashing “HHH” or “LLL”. The maximum and minimum recorded temperatures and humidities will be automatically stored in memory.
  • Page 9: Atmospheric Pressure

    COMFORT LEVEL INDICATORS ATMOSPHERIC PRESSURE The comfort level indicators COMFORT, WET or DRY will tell you The atmospheric pressure indicator in the weather forecast window, if the curent environment is comfortable, too wet or too dry. uses arrows to indicate if the atmospheric pressure is increasing, remaining stable, or decreasing.
  • Page 10: How To Wall Mount Or Use The Table Stand (Remote Unit)

    HOW TO WALL MOUNT OR USE THE HOW TO CHECK THE BAROMETRIC TABLE STAND (REMOTE UNIT) PRESSURE The unit can be wall-mounted using its recessed screw holes or The current and historical barometric pressure is shown on the place on a flat surface using the fold out table stand. atmospheric pressure window.
  • Page 11: How To Reset The Unit

    HOW TO RESET THE UNIT SPECIFICATIONS The RESET slot allows you to return all settings to factory values. Temperature Measurement Accessing the slot is required only when the unit is not operating Main unit in a favorable way such as in the rare case of a malfunction. Indoor Temperature measurement The RESET slot is located inside the battery compartment door.
  • Page 12: Note On Compliance

    Relative Humidity measurement NOTE ON COMPLIANCE Measuring Range : 25 to 95%RH Warning: Changes or modifications to this unit not expressly at 25°C (77°F) approved by the party responsible for compliance could void the Resolution of Humidity : 1% RH user’s authority to operate the equipment.
  • Page 13 MODEL: BAR913HG DIGITAL WEATHER FORECASTER WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK Instruction Manual **** Mode D'emploi **** Bedienungsanleitung **** Manuale di Istruzioni **** Instrucciones de Funcionamiento 913hg-e.p65 07/12/2001, 3:06 PM...
  • Page 14 COUNTRIES RTTE APPROVAL COMPLIED: Austria, Belgium, Denmark, Finland, France, Germany, Greece, Italy, Luxembourg, Netherlands, Portugal, Spain, Sweden, UK and Ireland. 913hg-e.p65 07/12/2001, 3:06 PM...