HID312 and HID525 50 Hz
Installation and User's Manual

Installation

Installation should be done by an experienced ice
machine installer. To locate one, call the number on
the back of this manual or go to Scotsman's website
www.scotsman-ice.com to identify a local distributor or
service company.
The machine will require power, water and drain.
Locate the water supply fitting on the lower back of
the cabinet and obtain the correct fitting to connect
the water supply.
Plumbing Fittings:
• The water supply connection is at the back panel,
50 Hz models have a single 3/4 gas BNF inlet water
connection and a connecting hose is supplied.
Note: New connecting hose is supplied do not re-
use old hose set
Drain Tubing
Power
Cord
Air Cooled Utilities
All models:
Connect the potable water supply to the inlet
at the bottom back of the unit. 3/8" OD tubing
recommended. Water filters may be used but are not
required. Note that activated carbon or charcoal water
filters are used for taste and odor problems but also
take out any chlorine that the local water agency may
have added for purification. That can require more
frequent sanitization of the equipment.
Connect drain tubing to the central drain fitting at the
Potable Water
Connection
July 2015
Page 8
back of the cabinet. Use 3/4 inch rigid tubing, use
material to meet local codes. The drain basin in the
machine will act as an internal vent, no additional
vent should be required unless there is a very long
horizontal run. Drain tubing must pitch down 1/4 inch
per foot to the building drain. Insulation of drain tubing
is recommended for most environments.
Electrical Supply
Power Cords:
50 Hz models are equipped with a cord without plug.
When adding a plug,
connect the plug to the power
cord in compliance with the local electrical codes.
Select an appropriately certified plug based on the
country of use, current rating of the appliance and
suitability for use with 1.5 mm 2 x 3 conductor type
H05VV-F cord
Note: In case the power cord is damaged, it
must be replaced by a like cord. Replacement
cords are available from the manufacturer's local
representative. Replacement should only be done
by a qualified technician to prevent possible risks.
The disconnection from the supply mains has
a contact separation in all poles that provides
full disconnection under overvoltage category III
conditions. The devices for disconnection must be
incorporated in the power supply line in accordance
with wiring rules.
Position the unit in its final location.
Level the unit front to back and left to right.
Seal to the countertop as required per local codes.