Inspection; Fluid Levels; Mechanical - MULTIQUIP WHITEMAN HTXD6i Manual

Hydraulic ride-on trowel (yanmar 4tnv84t-z-dsa2 diesel engine)
Hide thumbs Also See for WHITEMAN HTXD6i:
Table of Contents

Advertisement

FlUID levelS

Record the following fluid levels on Machine Information and
Maintenance Log in Inspection section. Refer to Fluid Fill and
Check section for procedure.
„ Engine Oil
„ Engine Coolant
„ Hydraulic Oil

MeCHaNICal

1. grease points — Ensure that the following Grease
Points are greased, wiped down and capped:
• Thrust Collar
• Fingers
2. Stabilizer rings
a. Verify at least 1 thread is visible below lower bolt
on all heim joints (Figure 43).
Figure 43. Visible Thread
b. Verify heim joint is centered, and not rotated, when
bolted on Figure 44).
Figure 44. Heim Joint Orientation
page 28 — HTXD6i/STXD6i Trowel • SeTUp, aDJUSTMeNTS aND CalIBraTIoNS — rev. #0 (03/14/13)
3. Hydraulics
• Spot check paint marks on fittings.
• Ensure that there are no leaks.
4. retardant Spray System
• Fill with water and perform operational check.
• Verify no leaks.
5. electrical (Cooling Fan)
• Verify fan cycles on when key is turned on
(will remain on for 10s).
• Verify air flow direction is outward.
6. lights
• Verify operation of all 6 machine lights.
7. Switches
• Verify proper operation of all switches.
8. Indicators
• Verify illumination when key is turned on
(will remain on for 10s)
• Red Stop Lamp
• Amber Warning Lamp
• Pitch Mode Light
• Cruise Control Light
• Coolant Temp
• Aux 1
• Aux 2
9. aesthetics
• Paint Quality
- No bare spots
- No scratches
• Decals
- Readable
-Not torn or scratched

inspection