Dyna-Glo WK95C6C Manual
Also See for WK95C6C:

Advertisement

Dyna-Glo WK95C6C Manual

WK95C6C


Before the first use of this heater, please read this OWNER'S MANUAL very carefully. This OWNER'S MANUAL has been designed to instruct you as to the proper manner in which to assemble the heater, maintain the heater, store the heater, and most importantly, how to operate the heater in a safe and efficient manner, please keep this manual for future reference.
GHP Group, Inc.,
Niles, IL 60714-3302, USA
TELEPHONE: 1-877-447-4768

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!

CAUTIONS - SAFETY GUIDE

  1. burn hazardburn hazard
    RISK OF EXPLOSION / RISK OF FIRE
    warning NEVER use any fuel other than water-clear 1-K kerosene or red dyed 1-K kerosene.
    warning NEVER use fuel such as gasoline, benzene, paint thinners or other oil compounds in this heater.
    warning NEVER refill heater fuel tank when heater is operating or still hot.
    warning NEVER use heater in areas where flammable vapors or gases may be present. ! NEVER fill heater fuel tank in living space; fill tank outdoors.
    warning NEVER store or transport kerosene in other than a metal or plastic container that is (1) acceptable for kerosene, (2) non-red in color, and (3) clearly marked "Kerosene". NEVER store kerosene in the living space; kerosene should be stored in a well ventilated place outside the living area.
    warning The unit is EXTREMELY HOT while in operation. Due to high surface temperatures, keep children, clothing, furniture, and other combustible objects at least 36 away from top and front area.
    warning RISK OF INDOOR AIR POLLUTION USE HEATER ONLY IN WELL VENTILATED AREAS. People with breathing problems should consult a physician before using the heater. In a house of typical construction, that is, one that is not of unusually tight construction due to heavy insulation and tight seals against air infiltration, an adequate supply of air for combustion and ventilation is provided through infiltration; however, if the heater is used in a small room where less than 200 cubic feet (5.7 m of air space is provided for each 1,000 BTU per hour of heater rating (considering the maximum burner adjustment), the door(s) to adjacent room(s) should be kept open or the window to the outside should be opened at least 1 inch (25.4 mm) to guard against potential buildup of indoor air pollution. DO NOT use the heater in a bathroom or any other small room with the door closed.
    warning NEVER use heater to heat or boil water or use as a cooking appliance.

  2. FAILURE TO INSTALL, MAINTAIN, AND/OR OPERATE THIS KEROSENE HEATER ACCORDING TO MANUFACTURER'S INSTRUCTIONS MAY RESULT IN CONDITIONS WHICH CAN PRODUCE BODILY INJURY AND/OR PROPERTY DAMAGE.
    NOTE:
    The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution, and carefulness are factors which cannot be built into this heater. These factors must be supplied by the person(s) installing, maintaining, or operating the kerosene heater.
    Always contact your dealer, distributor, service agent, or the manufacturer on any problems or conditions you do not understand.
    warning NEVER leave heater operating if you intend to leave for any period of time. Always make sure to turn heater off and inspect to insure that it is completely extinguished prior to going to bed.
    warning NEVER leave heater unattended.
    warning NEVER use as a source of heat for drying objects.
    warning NEVER place objects on the top plate.

  3. RISK OF BURNS
    warning NEVER operate the heater without the guard or grill completely attached.
  4. IF POOR QUALITY KEROSENE is used a rapid accumulation of carbon and tar is likely. This may cause a strong odor and will destroy the wick. Additional heater damage may occur as the wick becomes more difficult to adjust. The use of poor quality fuel could also make the wick very hard to extinguish. Always make sure the fire is out. (See Extinguishing the Heater.)
  5. ADJUSTMENT OF ROOM TEMPERATURE cannot be changed by adjusting the heater. A Kerosene heater is either on or off. There is no temperature adjustment. If heater output is reduced by lowering the wick in any way, improper combustion will occur producing odors and an accumulation of tar and carbon. If your room becomes too hot, open a door or a window or turn off the heater.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE!

INTRODUCTION

Please read this OWNER'S MANUAL carefully. It will show you how to assemble, maintain, and operate the heater safely and efficiently to obtain full benefit from its many built-in features.

FEATURES

FEATURES
Fig. 1

UNPACKING AND ASSEMBLY


"RISK OF BURNS"
DO NOT OPERATE HEATER WITHOUT INSTALLING THE PROTECTIVE GUARD OR GRILL.

  1. REMOVE THE HEATER AND ALL PACKING MATERIALS FROM THE BOX. (Fig.2)
    UNPACKING AND ASSEMBLY Fig. 2
    Fig. 2
    NOTE: Save the shipping carton and packing materials for future storage.
    • Heater.
    • Top guard.
    • Handle.
    • Top plate.
    • 2 "C" cell batteries.
    • Siphon pump.
    • Bag of screws for top grill assembly.
    • Owner's manual.
    • Safety Tips Manual.
  2. ASSEMBLING.
    1. Remove all packing materials from heater: (Fig.3)
      UNPACKING AND ASSEMBLY Fig. 3
      Fig. 3
    2. MOUNTING TOP PLATE: (Fig.4)
      UNPACKING AND ASSEMBLY Fig. 4
      Fig. 4
      Align the arrow marking on the top plate with the carrying handle hole on the cabinet and place the top plate on the cabinet.
    3. INSTALLING FRONT AND REAR GUARDS: (Fig.5A and Fig.5B)
      • Hang the upper portion of the front guard (notched to allow for the igniter door) on the Upper Grill brackets with the downward hooked grill rods. (Fig.5A)
        UNPACKING AND ASSEMBLY Fig. 5A
        Fig. 5A
      • Snap the lower portion of the front guard into the holes in the Lower Grill brackets with the inward hooked grill rods. (Fig.5B)
        UNPACKING AND ASSEMBLY Fig. 5B
        Fig. 5B
      • Install the rear guard in the same way.
    4. INSTALLING CARRYING HANDLE: (Fig.6)
      UNPACKING AND ASSEMBLY Fig. 6
      Fig. 6
      Insert the carrying handle into the holes on thecabinet by aligning holes on brackets of top plate.
    5. INSTALLING TOP GUARD: (Fig.7)
      UNPACKING AND ASSEMBLY Fig. 7
      Fig. 7
      • Align the 2 brackets on the top guard with the 2 mounting brackets on the front and rear guards.
      • Secure each bracket with a screw. Make sure that the brackets on the top guard are positioned outside the mounting brackets on the front and rear guards.
    6. INSTALLING BATTERIES: (Fig.8)
      UNPACKING AND ASSEMBLY Fig. 8
      Fig. 8
      • Battery holder is located on the back of the heater.
      • Open the battery cover from the battery case.
      • Insert two(2) "C" cell batteries according to the plus(+) and minus(-) markings inside of the holder.
      • Replace the battery cover to the heater.
    7. Now your heater is completely assembled: (Fig.9)
      UNPACKING AND ASSEMBLY Fig. 9
      Fig. 9

KEROSENE (1-K ONLY)

It is EXTREMELY IMPORTANT to the operation of this heater that you use the proper grade of kerosene. The proper grade of kerosene is identified as 1-K Kerosene. DO NOT OPERATE THIS HEATER WITH ANY FUEL OTHER THAN 1-K KEROSENE! 1-K Kerosene has been refined to virtually eliminate contaminants such as sulphur, which can cause a rotten egg odor during operation of the heater.

KEROSENE SHOULD ONLY BE STORED IN A BLUE CONTAINER THAT IS CLEARLY MARKED "KEROSENE". NEVER STORE KEROSENE IN A RED CONTAINER. Red containers are associated with gasoline.
NEVER store kerosene in the living space. Kerosene should be stored in a well ventilated place outside the living area.
NEVER use any fuel other than water-clear 1-K kerosene.
NEVER use fuel such as gasoline, benzene, alcohol, white gas, camp stove fuel, paint thinners, or other oil compounds in this heater. These are volatile fuels that can cause explosion or uncontrolled flames.

The best way to purchase kerosene is in a pre-packaged, metal or plastic, blue colored container.
The second choice would be to buy it from a dealer who stores it in a 55 gallon drum. The third choice is to buy kerosene from a dealer who stores it in a large underground (or above ground) tank. Kerosene that is contaminated with even a small amount of water will prevent a kerosene heater from functioning properly.
As you move from the first choice in purchasing kerosene (pre-packaged container) to the third choice (large storage tank), the likelihood of water being present from condensation increases.
If you purchase kerosene in bulk, know your dealer.

It is normal for a kerosene heater to give off a slight odor upon start-up and shut-down.
After 5-10 minutes of operation, the heater should have reached its normal operating temperature and any odor should be very slight.
NEVER store kerosene in direct sunlight or near a source of heat.
NEVER use kerosene that has been stored from one season to the next. Kerosene deteriorates over time. "OLD KEROSENE" WILL NOT BURN PROPERLY IN THIS HEATER.

A variety of problems can result from using poor quality kerosene --- smoke, odor, low flame, difficult ignition, difficult shut-down, flame flickers and dies, excessive burning down of the wick, reduced wick life, wick adjuster sticking, excessive deposits on the wick, etc.. If you encounter any of the problems listed above, check your kerosene. If you discover that the kerosene is the problem, get a fresh supply of WATER-CLEAR 1-K KEROSENE OR RED DYED 1-K KEROSENE before using your heater again.

FUELING YOUR HEATER

NEVER FILL THE HEATER FUEL TANK IN THE LIVING SPACE: FILL THE TANK OUTDOORS.
Before fueling the heater, take the heater, the kerosene, and the manual siphon pump outdoors. To use the manual siphon pump, tighten the cap on the top of the siphon, place the straight tube into the kerosene container, and insert the flexible tube into the opening of the fuel tank. By squeezing the bulb of the siphon pump, fuel will be transferred from the kerosene container into the heater tank (Fig.10). Carefully watch the fuel gauge on the base of the heater so that you will know when the tank is getting full. When you approach the full mark, loosen the cap on top of the siphon pump. This will stop the flow of kerosene. DO NOT OVERFILL YOUR HEATER. Allow the siphon pump to drain thoroughly before you remove it from the tank and the kerosene container.
FUELING YOUR HEATER Fig. 10
Fig. 10
After fueling the fuel tank of the heater by using siphon pump, make sure that you loosen (counter clock wise) the cap on the siphon pump to drain throughly the remaining kerosene in the siphon pump. For the reuse of siphon pump, make sure that you tighten (clock wise) the cap on the siphon pump to transfer the kerosene into the fuel tank properly. (Fig.11)
FUELING YOUR HEATER Fig. 11
Fig. 11
IMPORTANT NOTICE REGARDING FUELING OF THE HEATER: When fueling your heater for the first time and any other time when the tank has been completely empty, as in "Dry Burning" make sure to allow the wick to soak a minimum 60 minutes before you attempt to light the heater. Take note of the time you started to soak the wick or use a kitchen timer or wrist watch with an alarm feature. Failure to properly soak the wick can trap air pockets in the wick causing the heater to burn poorly. Premature ignition can destroy your wick.
IMPORTANT NOTICE REGARDING FIRST IGNITION OF HEATER
The first time you light your heater there may be some odor due to the burning off of oils used in the manufacturing process. To avoid this you may wish to burn the heater outside on a calm and windless day. If it s windy consider a porch or garage or other room where the windows can be open to disperse the odor.

AUTOMATIC IGNITION SYSTEM

For safety and convenience, this heater features an automatic ignition system.
2 "C" cell batteries, included with the heater, provide the power for the igniter which lights the wick once it has been raised to its maximum height.
To use the automatic ignition system:

  • Make sure the batteries have been installed.
  • Turn the wick adjuster knob clockwise until the wick has been raised to its maximum height. (Fig.12)
    AUTOMATIC IGNITION SYSTEM (Fig. 12)
    Fig. 12
  • Push the ignition lever (Fig.13) to bring the glowing igniter into contact with the wick. This will cause ignition to occur.
    AUTOMATIC IGNITION SYSTEM (Fig. 13)
    Fig. 13
  • As soon as you see that the wick has been lit, release the ignition lever. This will automatically lower the burn chamber back down over the wick.
  • Rotate the burner knob from side to side a few times to make sure that the burner is positioned properly on the wick adjuster.
  • Then begin following the steps outlined in "Adjusting the wick"

IGNITION VIA MATCH

If you encounter a problem with the ignition mechanism, or if you have dead batteries, it is possible to light the heater with a match. (Fig.14)
IGNITION VIA MATCH (Fig.14)
Fig. 14
The procedure is as follows:

  • Turn the wick adjuster knob clockwise until the wick has been raised to its maximum height.
  • Lift the burn chamber by using the burner knob.
  • Touch a lighted match to the exposed top edge of the wick.
  • Once you see that the wick has been lit, lower the burn chamber back down over the wick.
  • Rotate the burner knob from side to side a few times to make sure that the burner is positioned properly on the wick adjuster.
  • Then begin following the steps outined in "Adjusting the wick"


Make sure that you do not leave the match, or any portion of it (match head, etc.) in the burner area. Debris left from the match can cause an uneven alignment of the burner and may result in smoke, incomplete combustion, odor, or fire.

IGNITION VIA MATCH Step 1IGNITION VIA MATCH Step IGNITION VIA MATCH Step 3

CHECKING THE IGNITION SYSTEM

If the automatic ignition system fails to operate properly, perform the following checks:

  • BATTERIES -2 "C" cell batteries are located at the rear of the heater.
    Replace with new batteries.
  • IGNITER PLUG - If the automatic ignition system still doesn't work after replacing the batteries, check the igniter plug. If the glow coil filament is broken, bent, or doesn't glow when engaged via the ignition lever, it must be replaced.

    Be sure igniter plug is Type "B", 2.5V DC, 1A only.

To replace the igniter plug (Fig.15):
CHECKING THE IGNITION SYSTEM
Fig. 15

  • Remove the batteries.
  • Remove the 2 cabinet screws and lift off the cabinet and grill assembly.
  • Pull the ignition lever to raise the igniter plug.
  • Push the igniter plug in and turn in a clockwise direction to remove.
  • Install a new igniter plug (Type "B", 2.5V DC, 1A only) by pushing it in and turning it in a counter-clockwise direction.
  • Reassemble the heater and replace the batteries.
    TEST IGNITION
  • Using the wick adjuster knob, raise the wick to its maximum height.
    Pull the ignition lever.
    The igniter plug should be within 1~2mm of the wick when the ignition lever is fully engaged.

ADJUSTING THE WICK

After lighting the heater, it is important to check the heater flame within the first 5-7 minutes of operation. During the first 5 minutes after ignition, the burner chamber warms up and flames will become visible at the top of burner. These flames will gradually build up. After 5-7 minutes of operation, you should use the wick adjuster knob to obtain the proper flame height. The proper flame height is a 1/2" flame above the center flame spreader disk, with even distribution of flame around the flame spreader disk visible through the clear window of the heater. See pictures below for reference.
As you continue to operate the heater, the temperature of the heater and the temperature of the room will continue to change. As the heater warms up, the kerosene in the tank will vaporize faster, and this could require adjusting the wick adjuster down in order to maintain the desired 1/2" flame height. Therefore, it is necessary to continue to monitor the flame height, and to make adjustments using the wick adjuster knob to keep the proper flame height. It is recommended that the heater be checked every 30 minutes in order to keep the proper adjustment because periodic adjustment is required.

CORRECT FLAME
Proper combustion


FLAME TOO HIGH
Can Produce smoke and soot


FLAME TOO LOW
Can produce odor and carbon monoxide

Fig.16


NOTE: NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING.
Always make sure to turn the heater off and inspect it to insure that it is completely extinguished prior to going to bed.

NOTE: During start-up, small adjustments to the flame can be performed by using the burner knob on the front of the burner and MOVING THE BURNER FROM SIDE TO SIDE until the flame at the top of burner is as even as possible. THIS HEATER WILL PRODUCE SOOT AND SMOKE IF THE BURNER IS NOT SEATED PROPERLY. DO NOT TOUCH THE BURNER KNOB ONCE THE HEATER HAS REACHED NORMAL OPERATING TEMPERATURE AND THE FLAME HAS STABLIZED. THE BURNER KNOB IS VERY HOT DURING OPERATION.

ADJUSTING THE WICK Fig. 17
Fig. 17


NOTE: This heater is designed to operate with a flame height of a 1/2" above the flame spreader disk at the top of the burner. For proper combustion to occur, it is very important that the flame height be adjusted so that it is neither too high, nor too low. Operating the heater at a wick setting below the minimum recommended setting (the wick-stop setting) can result in the risk of carbon monoxide poisoning.

NOTE: If you find that the wick will not raise, push the safety reset lever to engage the safety shut-off device. Then dial the wick up via the wick adjuster knob.


RISK OF INDOOR AIR POLLUTION AND FIRE, DO NOT OPERATE HEATER AT WICK SETTING LOWER THAN MINIMUM WICK-STOP SETTING OR WITH AN EXCESSIVE FLAME HEIGHT.

WICK MAINTENANCE / DRY BURN

Wick maintenance is necessary to prevent soot production, low heat output and performance issues. Carbon and tar will build up on the top of the wick during regular use of this product. Wick maintenance is required within the first seven (7) days of your first use of the heater and every 2 tankfuls of fuel and/or every week during the heating season. If the wick feels hard and brittle, this indicates that wick maintenance is necessary in order to keep your heater performing accordingly.

Check Your Wick Often!

  • If the wick is hard to light.
  • If the wick is hard to raise or difficult to adjust by turning the wick adjustment knob.
  • If the wick fails to drop completely when you press the shut-off knob.
  • If the top of the wick is stiff and hard.

Note: Poor fuel or fuel contaminated with water will also turn the wick hard.

PERFORMING WICK DRY BURN / REMOVING CARBON FROM THE WICK

"Dry burning" your heater will cause a strong odor. For this reason it is best to " dry burn completely calm and windless. If it s too windy outside you can consider a porch, breezeway or other room with all of the windows open to disperse the strong odor.

Step 1
With your fuel tank nearly empty, burn your heater (without refilling) until the flame starts to burn out then raise the wick to its highest possible setting and leave it there until it burns out completely. Wait 60 minutes, then re-light the wick (with a match if necessary) and allow it to burn out again. Once the heater is cool to the touch, remove the cabinet and brush the top of the wick with an old tooth brush or other stiff bristle brush to remove any remaining ash. A canister type vacuum cleaner may be a useful tool in removing this ash.

Step 2
The first step should remove most carbon and your wick should feel softer to the touch. If any part still feels hard, you can use small pliers to pinch these hard spots and break up the carbon into pieces. After doing this, replace the cabinet, add a small amount of fuel, wait at least one hour and then repeat step 1.
Carry out Carbon Removal / Dry Burning within (7) seven days after your first use of your new heater to reduce carbon build-up on the wick's burning surface, after every two tankfuls of fuel and/or every week during the heating season. Afterwards, dry burn your heater anytime the wick appears to be hard. CHECK YOUR WICK OFTEN! Dry burn your wick and remove all fuel from your heater at the end of the heating season.

Note: Burn your heater dry, as noted above, weekly during the heating season or necessary thereafter. Check your wick often to see if CARBON REMOVAL / DRY BURNING is necessary. Carbon removal will NOT be effective if your fuel has been contaminated by water or any other liquid. In this case you must clean the fuel tank, replace the wick and soak it for 60 MINUTES in fresh, K-1 Kerosene.

WICK ASSEMBLY

Check at least once a month!

The burner assembly sits on top of the wick guide. Over time, tar deposits can accumulate on the wick guide, and this can prevent the burner assembly from seating properly. This can result in poor combustion, smoke, odor, etc.. To prevent this from happening, tar deposits on the wick guide can be removed as follows:

  • Making sure that the heater is both cool and turned off, lower the wick to the "off" position.
  • Remove the batteries (located at the rear of the heater).
  • Remove the 2 cabinet screws. Lift off the cabinet and grill assembly as shown in illustration. (Fig. A)
    WICK ASSEMBLY Fig. A
    Fig. A
  • Using the wick adjuster knob, raise the top of the wick until it is even with the top of the wick guide. Using a flat-edge screwdriver, scrape off the tar deposits. Be careful not to allow any of the tar deposits to drop into the grooves of the wick guide. A small vacuum cleaner can be used to remove the tar deposits that have been scraped off. (Fig. B)
    WICK ASSEMBLY Fig. B
    Fig. B
  • Reassemble the heater and replace the batteries.

WICK REPLACEMENT

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist: slow to light, hard movement of the wick adjuster knob, kerosene odor while burning, low heat output, slow warm up, damaged wick.

Use only a genuine replacement wick.
REPLACEMENT WICK NUMBER: Kero-World 32225, Dura Heat DH-145, Glowick 30856.

If cleaning the Wick does not improve performance, you will need to replace the wick. Refer to the "TROUBLE SHOOTING GUIDE", which outlines conditions under which the wick should be replaced.
DO NOT attempt to substitute any other type of wick device or a wick designed for another brand or model heater. You could damage the heater and create a potential fire hazard.
Call customer service at 1-877-447-4768, to order a wick.

warning ATTENTION: The only tools needed to replace the Wick are:

  • A pair of pliers
  • A flat blade screwdriver
  • A plastic bag with a twist tie

Visit our website at: www.ghpgroupinc.com/heaters/faqs.aspx and select RMC-95C6 /RMC-95C6B for a link to a detailed video demonstrating wick replacement.

  1. Push down the manual shut-off knob and turn the wick adjustment knob COUNTERCLOCKWISE in the direction of "OFF".
    WICK REPLACEMENT Step 1
  2. Use a screwdriver to loosen and remove cabinet screws on either side of the heater cabinet.
  3. Use the carrying handle to lift the cabinet straight up and away from the heater.
    WICK REPLACEMENT Step 2
  4. Gently pull the wick adjustment knob off the heater.
    WICK REPLACEMENT Step 3
  5. Remove the cabinet base by lifting it from the back and tilting it forward to clear the wick adjuster assembly.
    WICK REPLACEMENT Step 4
  6. Trip the pendulum on the automatic safety shutoff system to lower the wick.
    WICK REPLACEMENT Step 5
  7. Remove the four wing nuts which hold the wick assembly to the heater and carefully lift the wick assembly from the heater.
    WICK REPLACEMENT Step 6
  8. Replace the wick adjustment knob temporarily. Turn the knob CLOCKWISE to raise the wick.
  9. Hold the wick assembly up-sidedown, using caution, grasp the wick cover firmly PULL it off with a sharp tug. If you have difficulty doing so, try loosening the wick cover with a flat blade screwdriver.

    The inside of wick cover has sharp teeth. The use of work gloves is suggested to avoid injury.
    WICK REPLACEMENT Step 7
  10. Remove the wick by folding it to the inside. Then remove the wick sleeve from the bottom of the assembly.
    WICK REPLACEMENT Step 8
  11. Install the new wick and insert the 3 pins on a new wick into the 3 holes on the wick sleeve in the upward direction. (See the arrow marked "🡅 up" on the wick sleeve)
    WICK REPLACEMENT Step 9
  12. Push the new wick into the retainer teeth of the wick sleeve so that the wick adheres tightly around the inside of the wick sleeve, smoothing out any wrinkles.
    WICK REPLACEMENT Step 10
    NOTE: DO NOT DISASSEMBLE THE STAINLESS STEEL WICK HOLDER.
  13. Line up the pins with the slotted holes inside the wick adjuster. Then lightly press each of the three pins of the wick (now attached to the wick sleeve) toward the center, away from the slanted grooves of the wick adjuster allowing the wick do drop slightly. Once the pins line up with each hole, press firmly on each pin toward the slanted grooves securely through each hole.
    WICK REPLACEMENT Step 11
    NOTE: Turn the wick adjustment knob and check to be sure that the wick moves up and down freely.
  14. The wick height will automatically be set to the correct burning height of 3/8" (10mm).
    WICK REPLACEMENT Step 12
    NOTE: Be sure to check wick height. It should be 3/8".
  15. Turn the wick assembly upside down to replace the wick cover.
  16. Align the tabs on the wick cover with the four screw holes on the bottom of the assembly, as shown, and snap it into place. Be certain of firm contact at all points.
  17. Be sure the rubber seal on tank is properly seated. <Fig. B>
    WICK REPLACEMENT Step 13
    Fig. B
  18. (1) Turn the wick adjustment knob to the fully raised position. (2) Pull lightly on the skirt of the wick to remove any slack. (3) Press lightly to secure the skirt to the retainer teeth on the wick cover. (4) You will need to hold the knob in the clockwise position to keep the wick raised. <Fig. A>
    WICK REPLACEMENT Step 14
    Fig. A
    WICK INSTALLATION TIP
    ** Lock the tip over switch (TOS) by inserting locking pliers or a clothes pin between the TOS plates, preventing the weight from triggering the TOS mechanism as you install the new wick. Install the new wick in the raised position. Remember to remove pliers or clothes pin before reassembling & lighting heater.
  19. (5) Replace the wick assembly on the heater with the wick raised. (6) The wick adjuster knob will need to be positioned between the caution and warning labels. <Fig. C> (7) Replace two diagonally opposite wing nuts first. (8) Then the remaining two. (9) Tighten each of the four wing nuts gradually until the wick assmbly is firmly in place.
    WICK REPLACEMENT Step 15
    Fig. C
    WICK REPLACEMENT Step 16
  20. While your heater is disassembled, check the Automatic Safety Shutoff system. Remove the locking pliers or clothes pin from the TOS mechanism if you used them to assist with the wick installation. Trip the automatic shutoff system by nudging the pendulum. Raise the wick by turning wick adjuster knob. Trip it again to make certain it is operating correctly.
  21. Turn the Wick Adjustment knob to test its operation. Be certain the Wick operates smoothly as the knob is turned CLOCKWISE and COUNTER-CLOCKWISE.
  22. Test Ignition. Raise the Wick to its full height. The Ignition Plug should be within 3/64" to 5/64" (1 mm to 2 mm) of the Wick when the Lever is pulled.

    Do not touch the HOT, glowing ignitor!
  23. Be sure to check that the wick is set at the correct height of 3/8" (10 mm)
  24. Remove Wick adjustment knob which you had temporarily replaced to test wick operation.
  25. Replace the cabinet base making certain to align the automatic safety shutoff system lever and the wick adjustment shaft, which holds the knob, with the appropriate slots in the cabinet base. Begin by aligning them and gently snap the cabinet base in place over the wick assembly.
  26. Replace the heater cabinet. Make certain the grill guard prongs are inserted securely into the proper holes on the heater, and the front cabinet matches the front of the heater.
  27. Fasten the cabinet to the heater with the two screws.
  28. Replace the wick adjustment knob. To be certain it is properly positioned on the wick adjustment shaft, raise the wick to its full height.

EXTINGUISHING THE HEATER

To extinguish the heater, push down on the manual shut-off knob (Fig.18) with one hand while holding the wick adjuster knob in the other hand. You will feel the pressure of spring action attempting to turn the wick adjuster knob in a counterclockwise direction in your hand. By slowly relaxing your grip on the wick adjuster knob, you will allow the spring to gradually lower the wick and extinguish the flame. When there is no further pressure from the spring action, confirm that the wick has been fully lowered by turning the wick adjuster knob in a counter-clockwise direction as far as it will go.
EXTINGUISHING THE HEATER
Fig. 18
After 10-15 seconds, open the door on the body of the heater, lift the burner using the burner knob, and visually confirm that there are no flames present. This will confirm that the heater is completely extinguished.


After extinguishing the heater, allow at least 10 minutes before reigniting the heater. This allows the heater time to cool off and return to a normal temperature. Failure to allow the 10 minute cooling off period before reigniting the heater will result in the creation of a strong odor and possible flare-up.


Carbon and tar can build up on the wick after the heater has been in use for a while. This can interfere with the ability of the wick to be lowered into the body of heater, and can result in the flame not extinguishing completely. It is the responsibility of the owner to inspect the wick, to maintain proper maintenance of the wick, and to replace the wick when necessary in order to prevent the build up of carbon and tar from creating a dangerous situation where the heater does not fully extinguish.

AUTOMATIC SAFETY SHUT-OFF DEVICE

This heater is equipped with an automatic safety shut-off device. The purpose of this device is to quickly and efficiently shut-off the heater should the heater be jarred or tipped over while in operation. This is the main safety system that is built into the heater, and it functions to prevent the flame from spreading if the heater is knocked over.
The automatic safety shut-off device is built into the mechanism that raises and lowers the wick. It has been designed so that if the pendulum is jarred by a shock of some sort, it retracts a latch from the wick control shaft ratchet, and a torsion spring reacts to drop the wick to its fully lowered position. This rapid lowering of the wick extinguishes the flame.
If you find that the wick will not raise, push the manual shut-off knob to engage the automatic safety shut-off device. Then dial the wick up via the wick adjuster knob.


IMPORTANT NOTICE: For the safety shut-off device to function properly, the wick must be free of carbon and tar deposits. Regularly performing the "Carbon Removal / Dry burning" procedure described in the "Wick Maintenance" and "Carbon Removal / Dry Burning" sections is very important to the proper functioning of this important safety device.


IMPORTANT NOTICE: PLEASE CHECK THE SAFETY SHUT-OFF DEVICE ONCE A WEEK DURING THE HEATING SEASON TO INSURE THAT IT IS FUNCTIONING PROPERLY.


IMPORTANT NOTICE: EVERY TIME THE WICK IS REMOVED OR REPLACED, THE SAFETY SHUT-OFF DEVICE MUST BE TESTED TO INSURE THAT IT IS FUNCTIONING PROPERLY.

TESTING THE SAFETY SHUT-OFF DEVICE: At least once a week during the heating season, it is important to test the safety shut-off device to be sure that it is operating properly. WITH THE HEATER TURNED OFF, raise the wick using the wick adjuster knob to the fully raised position. Grabbing the protective grill, give the heater a firm shake. If the safety shut-off device is working properly, you will hear a loud noise as the ratchet is disengaged and the torsion spring drops the wick into the body of the heater. To verify that the wick has been completely lowered, turn the wick adjuster knob in a counterclockwise direction. If the safety shut-off device is functioning properly, the wick will have been completely lowered. If you are able to lower the wick further using the wick adjuster knob, this means that it is time to perform the "Carbon Removal Dry Burning" procedure again.

LONG TERM STORAGE OF YOUR HEATER

Carefully following the instructions for storage given below will insure that your heater will operate efficiently and safely next season (Fig.19/ Fig.20).
LONG TERM STORAGE OF YOUR HEATER Fig. 19
Fig. 19
LONG TERM STORAGE OF YOUR HEATER Fig. 20
Fig. 20

  • Using a small amount of kerosene, swirl and rinse the inside of the tank. NEVER mix water with the kerosene as it will cause rust inside the tank. Pour the kerosene out making sure that you remove it all.
  • With the fuel tank empty, ignite the heater. With the wick at its maximum height, keep the wick burning until it burns out completely (about 1 hour). It is a good idea to do this outside or in an extremely well-ventilated area.
  • Remove the batteries. Remove the 2 cabinet screws and lift off the cabinet and grill assembly. Remove the burner. Remove the wick adjuster from the fuel reservoir. Thoroughly dry the inside of the fuel tank. Using a screwdriver and/or a brush, remove any carbon, tar or soot that might have accumulated on the wick adjuster, wick guide or burner.
  • After a thorough cleaning, reassemble the heater. It is important when reassembling the wick adjuster to be sure to maintain an equal gap between the wick adjuster and the wick guide cylinder all around. See "Wick Replacement" for reference.
  • Remove the batteries from the battery case before storing the heater to prevent leakage and corrosion.
  • Store the heater with the wick in the fully lowered position and the safety shut-off device deactivated.
  • Store the heater in the original box with the original packing material and keep the OWNER'S MANUAL with the heater. Store in an area that is well-ventilated.

TROUBLESHOOTING GUIDE

TROUBLE CORRECTIVE ACTION

Heater Will Not Light

  1. Fuel tank is empty
  2. Water present in kerosene
  3. Igniter plug fails to glow
  4. Igniter plug makes contact with side of wick
  1. Fill tank with water-clear 1-K kerosene or red dyed 1-K kerosene.
  2. Drain tank. Remove wick assembly & replace wick. Reinstall wick assembly. Fill tank with water-clear 1-K kerosene or red dyed 1-K kerosene.
  3. Replace batteries. Replace igniter plug. Check for broken or disconnected wire.
  4. Lower wick using wick adjuster knob until igniter plug makes contact with top of wick.

Heater Produces Smoke or Odor

  1. Flame is too high
  2. Heater is in an air draft
  3. Burner is not level
  4. Carbon or tar built up on wick
  5. Contaminated kerosene
  1. Using wick adjuster knob, lower wick to desired 1/2" flame.
  2. Move heater out of air draft.
  3. Using burner knob, rotate burner from side to side until it seats properly over wick.
  4. Perform "Carbon Removal / Dry Burning" procedure. Replace wick if necessary.
  5. Drain tank. Remove wick assembly & replace wick. Reinstall wick assembly. Fill tank with water-clear 1-K kerosene or red dyed 1-K kerosene.

Flame Flickers or Dies

  1. Water present in kerosene
  2. Carbon or tar built up on wick
  1. Drain tank. Remove wick assembly & replace wick. Reinstall wick assembly. Fill tank with water-clear 1-K kerosene or red dyed 1-K kerosene.
  2. Perform "Carbon Removal / Dry Burning" procedure. Replace wick if necessary.

Wick Burning Down Excessively

  1. Dangerous, volatile fuel mixed with kerosene (gasoline, benzene, alcohol, white gas, paint thinner, camp, stove fuel, oil compound)
  1. Drain and clean tank
    • Remove and replace wick
    • Fill tank with water-clear 1-K keroseneor or red dyed 1-K kerosene.

Wick Adjuster Sticks

  1. Water present in kerosene
  2. Carbon or tar built up
  1. Drain tank. Remove wick assembly & replace wick. Reinstall wick assembly. Fill tank with water-clear 1-K kerosene or red dyed 1-K kerosene.
  2. Perform "Carbon Removal / Dry Burning" procedure. Replace wick if necessary.

Wick will not raise

  • Push the safety reset lever to engage the automatic safety shut-off device.
    Then dial the wick up via the wick adjuster knob.

Heater is enveloped in flames

  • Call Fire Department.
  • Exit quickly and warn others.
  • DO NOT: Move heater, try to smother fire, or put water on fire.

EXPLODED PARTS DRAWING

NOTE: SPECIFY MODEL NUMBER AND PART NUMBER WHEN ORDERING PARTS.

EXPLODED PARTS DRAWING

PARTS LIST

DRAWING
NUMBER
DESCRIPTION PART
NUMBER
1 TOP GRILLE PS-CV01
2 CARRYING HANDLE WS-CV02R
3 TOP PLATE(WK95C6C) WS-CV03B
4 BURNER ASS'Y WS-CV04
5 WICK COVER WS-CV25
6 REAR GRILLE PS-CV060
7 CABINET BASE(WK95C6C) WS-CV12B
8 WIND COVER WS-CV17
9 WICK ADJUSTER ASS'Y (COMPLETE) 2113-0032-00
10 WICK See Below
11 WICK ADJUSTER GASKET PS-CV19R
12 SAFETY SHUT OFF DEVICE See 9
13 DRIP TRAY ASS'Y(WK95C6C) PS-CV32R1B
14 FUEL CAP GASKET WS-CV30
15 FUEL CAP ASS'Y WS-CV29
16 WICK ADJUSTER KNOB(WK95C6C) WS-CV14B
17 BATTERY CASE ASS'Y(WK95C6C) WS-CV27R1B
18 FRONT GRILLE PS-CV061
19 CABINET(WK95C6C) PS-CV08RB
20 MICA WINDOW WS-CV09
21 DOOR(WK95C6C) WS-CV34B
22 FUEL GAUGE WS-CV21
23 FUEL GAUGE GASKET WS-CV22
24 TANK ASS'Y(WK95C6C) PS-CV23R3B
25 IGNITER ASS'Y PS-CV24R1
26 WICK SLEEVE PS-CV35

SPECIFICATIONS

Model No. WK95C6C
Type of Heater Convection
Heat Output Max. 23,000 BTU/hr
Fuel Tank Integral
Tank Capacity 1.9 U.S. gallons
Continuous Combustion Time Approx. 8-12 hr
Max. Fuel Consumption 0.167 U.S. gallons/hr.
Ignition Method Battery-C Cell x2, Igniter Type "B"
Dimensions Height 27 inches
Width 17.5 inches
Depth 17.5 inches
Wick Height 25/64 IN. (10mm)
Replacement Wick Number Kero-World 32225, Dura Heat DH-145, Glowick 30856

Warranty

LIMITED WARRANTY:
This limited warranty is extended to the orginal retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc, at it's option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, In., within one (1) year of retail purchase. (Shipping cost, labour costs, etc. are the responsibilty of the purchaser.)

DUTIES OF THE OWNER:
This heating appliance must be operated in accordance with the written instructions furished with this heater. This warranty shall not excuse
the owner from properly maintaining this heater in accordance with the writen instructions furnished with this heater. A bill of sale, cancelled
check or payment record must be kept to very purchase date and establish warranty period. Original carton should be Kept in case of warranty
return of unit.

WHAT IS NOT COVERED:

  1. Damage resulting from use of improper fuel.
  2. Damage caused by misuse or use contrary to the owners manual and safety guidelines.
  3. Damage caused by a lack of normal maintenance.
  4. Fuses.
  5. Use of non-standard parts or accessories.
  6. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsiblity of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of
routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE, THE
REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL
GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not alow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not
allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

  1. Contact your retailer and explain the problem.
  2. If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof of date of purchase.
  3. A representative wil contact you. DO NOT RETURN THE HEATER TO GHP GROUP, INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state

REGISTER THE WARRANTY ON YOUR HEATER ON-LINE AT: www.ghpgroupinc.com


GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302
Tel: (877) 447-4768
www.ghpgroupinc.com

Brand

Videos

GHPG 95c6 / 95c6B Wick Replacement Video

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Dyna-Glo WK95C6C Manual

Advertisement

Need Assistance?

Do you have a question about the WK95C6C that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents