28
7CI100A/7FS100A, 15CI100A/15FS100A
Service Display
Condition
High amps
Contact Follett technical service
group at (877) 612-5086 or
+1 (610) 252-7301.
Note: For dispensers after serial
Internal leak in
Locate leak and repair - Press reset
dispenser
on control board. Contact Follett if
unit is leaking.
Sleep mode
Press either dispense button to
return to normal operation.
Procedure
number D45191, the phone
and wrench will not be
illuminated.