8)
Press the DOWN button.
Verify that the Channel A signal AND clip LEDs light, and that
when the button is held, that the LED pattern is in working order as in the
Front Panel Sub Assembly Test.
Problems with no response or flickering LEDs indicates poor or failed
mechanical fit for the switch, and the test has FAILED. Problems with the
appearance of the LEDs also indicates the test has FAILED.
Failure of this inspection indicate that the DUT cannot continue further
testing.
9)
Press the UP button.
Verify that the Channel B signal AND clip LEDs light, and that
when the button is held, that the LED pattern is in working order as in the
Front Panel Sub Assembly Test.
Problems with no response or flickering LEDs indicates poor or failed
mechanical fit for the switch, and the test has FAILED. Problems with the
appearance of the LEDs also indicates the test has FAILED.
Failure of this inspection indicate that the DUT cannot continue further
testing.
10)
Press the BYPASS button.
Verify that the Bypass LED lights, and that the LED pattern is in working
order as in the Front Panel Sub Assembly Test.
Problems with no response or flickering LEDs indicates poor or failed
mechanical fit for the switch, and the test has FAILED. Problems with the
appearance of the LEDs also indicates the test has FAILED.
Failure of this inspection indicate that the DUT cannot continue further
testing.
11)
Press the LINK button.
Verify that the Link LED lights, and that the LED pattern is in working
order as in the Front Panel Sub Assembly Test.
Problems with no response or flickering LEDs indicates poor or failed
mechanical fit for the switch, and the test has FAILED. Problems with the
appearance of the LEDs also indicates the test has FAILED.
Failure of this inspection indicate that the DUT cannot continue further
testing.
Confidential
Alesis Service Manual
8-31-0103-A