COLU and RT Fault Indicators

F
I
AULT
SOLATION
The following sections detail the fault isolation procedures. For sections that indicate a condition such as "distance
limitation exceeded", refer to
COLU
RT F
AND
At the CO, you can use the Craft interface to initiate a SDT to determine the cause of any of the following
problems. The SDT test performs Hazardous Potential, Foreign Voltage, Resistive Faults, Receiver Off-Hook, and
Ringers Tests. At the customer site, the following sections provide procedures for isolating faults indicated by the
COLU LEDs.
LED
Mode
Condition
None
On
processor in the COLU stopped 1 Remove and re-insert the COLU.
Fault
On
indicates an existing alarm
condition on the COLU
M
On
distance limitation exceeded
argi
n
fault in HDSL line
faulty COLU
M
Flashing distance limitation exceeded
argi
n
fault in HDSL line
faulty RT
SYNC Off
HDSL line has lost
synchronization
distance limitation may have
been exceeded
COLU is faulty
38
"Specifications" on page 2
I
AULT
NDICATORS
Procedure
2 At the VT-100 interface, go to the COLU Main screen to view the
Performance report to verify that no alarms exist. If the COLU Main
screen cannot be viewed, a communication error exists, indicating a
faulty COLU.
3 If the LEDs do not illuminate, replace the COLU.
1 At the VT-100 interface, go to the COLU Main screen to view the
Performance report to determine the cause of the alarm. Correct the
condition, if possible. If the COLU Main screen cannot be viewed, a
communication error exists.
2 Remove and re-insert the COLU.
3 If the communication error still exists, replace the COLU.
1 At the VT-100 interface, go to the COLU Main screen to view the
Performance report to verify that no alarms exist.
2 Initial installation, check engineering records for distance between COTS
and RT.
3 If existing installation, measure loss of HDSL line to ensure that the
maximum attenuation value has not been exceeded.
4 Replace COLU or the RT or both.
1 Initial installation, check engineering records for distance between COTS
and RT.
2 If existing installation, measure loss of HDSL line to ensure that the
maximum attenuation value has not been exceeded.
3 Replace the COLU or the RT or both.
1 Initial installation, check engineering records for distance between COTS
and RT.
2 If existing installation, measure loss of HDSL line to ensure that the
maximum attenuation value has not been exceeded.
3 Replace the COLU or the RT or both.