Ground Terminal

The generator ground terminal is connected to the frame of the
generator, the metal non-current-carrying parts of the generator, and
the ground terminals of each receptacle.
Before using the ground terminal, consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local codes
or ordinances that apply to the intended use of the generator.
NEUTRAL FLOATING:
• The generator (stator winding) is isolated from the frame and from
the AC receptacle ground pin.
• Electrical devices that require a grounded receptacle pin connection
will not function if the receptacle ground pin is not functional.