Summary of Contents for Honda EU26i

  • Page 1 Honda EU26i·EU30is OWNER’S MANUAL MANUEL DE L’UTILISATEUR BEDIENUNGSANLEITUNG MANUAL DE EXPLICACIONES The‘‘e-SPEC’’mark symbolizes environmentally responsible technologies applied to Honda power equipment, which contains our wish to ‘‘preserve nature for generations to come.’’...
  • Page 3 All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation.
  • Page 4: Table Of Contents

    High altitude operation GENERATOR USE ................28 STOPPING THE ENGINE ..............40 MAINTENANCE ................42 TRANSPORTING/STORAGE ............53 TROUBLESHOOTING ............... 55 SPECIFICATIONS ................57 WIRING DIAGRAM ................61 MAJOR Honda DISTRIBUTOR ADDRESSES ........ . 67...
  • Page 5: Safety Instructions

    SAFETY INSTRUCTIONS IMPORTANT SAFETY INFORMATION Honda generators are designed for use with electrical equipment that has suitable power requirements. Other uses can result in injury to the operator or damage to the generator and other property. Most injuries or property damage can be prevented if you follow all instructions in this manual and on the generator.
  • Page 6 Carbon Monoxide Hazards Exhaust contains poisonous carbon monoxide, a colorless, odorless gas. Breathing exhaust can cause loss of consciousness and may lead to death. If you run the generator in an area that is confined, or even partially enclosed area, the air you breathe could contain dangerous amount of exhaust gas.
  • Page 7 Fire and Burn Hazards Do not use the generator in areas with a high risk of fire. When installed in ventilated rooms, additional requirements for fire and explosion protection shall be observed. The exhaust system gets hot enough to ignite some materials. Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during operation.
  • Page 8 Do not throw it in the trash or pour it on the ground. An improperly disposed battery can hurt the environment. Always confirm local regulations for battery disposal. Contact your Honda servicing dealer for a replacement.
  • Page 9: Safety Label Locations

    These labels warn you of potential hazards that can cause serious injury. Read the labels and safety notes and precautions described in this manual carefully. If a label comes off or becomes hard to read, contact your Honda dealer for a replacement. G, GW, B, F types...
  • Page 10 Honda generator is designed to give safe and dependable service if operated according to instructions. Read and understand the Owner’s Manual before operating the generator. Failure to do so could result in personal injury or equipment damage. Exhaust contains poisonous carbon monoxide, a colorless, odorless gas.
  • Page 11 Stop the engine before refueling. Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. Keep away from cigarette, smoke and sparks when refueling the generator. Always refuel in a well ventilated location. Wipe up spilled gasoline at once.
  • Page 12 U type...
  • Page 13: Ce Mark And Noise Label Locations

    CE mark and noise label locations G, GW, B, F types CE MARK and NOISE LABL NOISE LABEL Manufacturer and address Performance class IP code Dry mass (weight) [Example: EU30is CE MARK and NOISE LABEL]...
  • Page 14: Component Identification

    COMPONENT IDENTIFICATION STAND TYPE FRONT COVER STARTER GRIP FRONT HANDLE PIPE GROUND TERMINAL CONTROL PANEL (See page 14) WHEEL TYPE WHEELS CONTROL PANEL (See page 14)
  • Page 15 MUFFLER FUEL FILLER CAP REAR HANDLE PIPE SPARK PLUG CAP OIL FILLER CAP AIR CLEANER OIL DRAIN PLUG FRAME SERIAL NUMBER OIL MAINTENANCE COVER LEFT SIDE MAINTENANCE COVER Record the frame serial number in the space below. You will need this serial number when ordering parts.
  • Page 16: Control Panel

    CONTROL PANEL F, G, GW types PARALLEL OPERATION RECEPTACLE DC CIRCUIT PROTECTOR AC OUTPUT INDICATOR LIGHT DC RECEPTACLE AC CIRCUIT PROTECTOR AC OVERLOAD INDICATOR LIGHT OIL ALERT INDICATOR LIGHT ENGINE SWITCH CHOKE KNOB FUEL VALVE LEVER AC RECEPTACLES ECO THROTTLE SWITCH B type U type AC RECEPTACLES...
  • Page 17 Eco Throttle ECO: Engine speed is kept at idle automatically when the electrical appliance is disconnected and it returns to the proper speed by the electrical load when electrical appliance is connected. This position is recommended to minimize the fuel consumption while in operation. When high electrical load appliances is connected simultaneously, turn the Eco Throttle switch to the OFF position to reduce voltage changes.
  • Page 18: Pre-Operation Check

    PRE-OPERATION CHECK Be sure to check the generator on a level surface with the engine stopped. Check the engine oil level. Using non detergent oil or 2-stroke engine oil could shorten the engine’s service life. Recommended oil Use 4-stroke motor oil that meets or exceeds the requirements for API service category SE or later (or equivalent).
  • Page 19 Open the oil maintenance cover. Remove the oil filler cap, and wipe the dipstick with a clean rag. Check the oil level by inserting the dipstick in the filler hole without screwing it in. If the oil level is below the end of the dipstick, refill with recommended oil up to the top of the oil filler neck.
  • Page 20 Check the fuel level. Check the fuel level gauge. Refill the fuel tank if the fuel level is low. After refueling, tighten the fuel filler cap securely. Use automotive unleaded gasoline with a Research Octane Number of 91 or higher (a Pump Octane Number of 86 or higher). Never use stale or contaminated gasoline or an oil/gasoline mixture.
  • Page 21 Gasolines Containing Alcohol If you decide to use a gasoline containing alcohol (gasohol), be sure its octane rating is at least as high as that recommended by Honda. There are two types of ‘‘gasohol’’: one containing ethanol, and the other containing methanol.
  • Page 22 Check the air cleaner. Check the air cleaner elements to be sure they are clean and in good condition. Open the left side maintenance cover. Unsnap the four clips, remove the air cleaner cover, remove the foam element from the air cleaner cover, and check the both elements.
  • Page 23: Starting The Engine

    STARTING THE ENGINE Electric starting (EU30is only) When starting the generator after adding fuel for the first time, after long-term storage, or after running out of fuel, turn the fuel valve lever to the ON position, then wait for 10 to 20 seconds before starting the engine.
  • Page 24 Turn the engine switch to the START position and hold it there until the engine starts. START ENGINE SWITCH Do not use the starter motor for more than 5 seconds. If the engine fails to start, release the key, and wait at least 10 seconds before operating the starter motor again.
  • Page 25 Push the choke knob to the OPEN position as the engine warms up. OPEN CHOKE KNOB...
  • Page 26 Manual starting When starting the generator after adding fuel for the first time, after long-term storage, or after running out of fuel, turn the fuel valve lever to the ON position, then wait for 10 to 20 seconds before starting the engine. Before starting the engine disconnect any load from the AC receptacle.
  • Page 27 Turn the engine switch to the ON position. EU30is ENGINE SWITCH EU26is ENGINE SWITCH...
  • Page 28 Pull the starter grip lightly until you feel resistance, then pull the starter grip briskly toward in the direction of the arrow as shown below. The starter grip can be drawn back very quickly before you release it. This may pull your hand forcefully toward the engine and cause an injury.
  • Page 29: High Altitude Operation

    If you always operate the generator at altitudes higher than 1,500 meters (5,000 feet) above sea level, have your authorized Honda dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each 300 meters (1,000 foot) increase in altitude.
  • Page 30: Generator Use

    GENERATOR USE Be sure to ground the generator when the connected equipment is grounded. Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician. Connections for standby power to a building’s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes.
  • Page 31 The DC receptacle can be used while the AC power is in use. If you use both at the same time, do not exceed the maximum AC power. Maximum AC power: EU26i: 2.25 kVA EU30is: 2.65 kVA Most appliance motors require more than their rated wattage for startup.
  • Page 32 AC applications Start the engine and make sure the green output indicator comes on. Confirm that the appliance to be used is switched off, and plug in the appliance. OUTPUT INDICATOR LIGHT (GREEN) OVERLOAD INDICATOR LIGHT (RED) Substantial overloading that continuously lights the overload indicator light (red) may damage the generator.
  • Page 33 AC Circuit Protector (B, F, and GW Types) The AC circuit protectors will automatically switch OFF (push button comes out) if there is a short circuit or a significant overload of the generator at receptacle. If an AC circuit protector switches OFF automatically, check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON (pushing the push button in).
  • Page 34 When an electric motor is started, both the Overload indicator (red) and the Output indicator (green) may go on simultaneously. This is normal if the Overload indicator (red) goes off after about five (5) seconds. If the Overload indicator (red) stays on, consult your Honda generator dealer.
  • Page 35 Power levels between rated and maximum may be used for no more than 30 minutes. Limit operation requiring maximum power to 30 minutes. Maximum power in parallel operation is: EU26i: 5,200 VA EU30is: 6,000 VA For continuous operation, do not exceed the rated power.
  • Page 36 Never connect the different generator models and types. Never connect a cable other than the special cable/receptacle for parallel operation. Connect and remove the special cable/receptacle for parallel operation with the engine stopped. For single operation, the special cable/receptacle for parallel operation must be removed.
  • Page 37 Be sure to ground the generator when the connected equipment is grounded. GROUND TERMINAL Start each engine according to ‘‘STARTING THE ENGINE’’. When the output indicator light (green) does not light and the overload indicator light (red) lights instead, set the engine switch to STOP, stop the engine once, and then start the engine again.
  • Page 38 Switch on the equipment to be used. The output indicator light (green) will light. In case of normal operation In case of overload operation or short-circuit OUTPUT INDICATOR LIGHT OUTPUT INDICATOR LIGHT (RED) (GREEN) In case of overload operation (refer to page ) or when trouble occurs for the equipment being used, the output indicator light (green) will go out, the overload indicator light (red) will light...
  • Page 39 (do not use the AC output) EU26i 10 A approximately 3.3 A EU30is 12 A approximately 4 A Connect the charging cable to the DC receptacle of the generator and then to the battery terminals. DC CIRCUIT PROTECTOR CHARGING CABLE (SOLD SEPARATELY) (Example: EU26i)
  • Page 40 To prevent the possibility of creating a spark near the battery, connect charging cable first to the generator, then to the battery. Disconnect cable first at the battery. Before connecting charging cable to a battery that is installed in a vehicle, disconnect the vehicle’s battery cable.
  • Page 41 Start the engine. The DC receptacle may be used while the AC power is in use. An overload DC circuit will trip the DC circuit protector (push button comes out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation.
  • Page 42: Stopping The Engine

    To stop the engine in an emergency, turn the engine switch to the OFF position. IN NORMAL USE: Switch off the connected equipment and pull the inserted plug. In parallel operation Turn the engine switch to the OFF position. EU30is ENGINE SWITCH EU26i ENGINE SWITCH...
  • Page 43 Turn the fuel valve lever to the OFF position. FUEL VALVE LEVER When parallel operation has been executed, remove the special cable/receptacle for parallel operation. SPECIAL CABLE/RECEPTACLE FOR PARALLEL OPERATION...
  • Page 44: Maintenance

    Replace paper element type only. Service more frequently when used in dusty areas. These items should be serviced by your Honda servicing dealer, unless you have the proper tools and are mechanically proficient. Refer to the Honda shop manual for service procedures.
  • Page 45 CHANGING OIL Drain the oil while the engine is still warm to assure rapid and complete draining. Open and remove the oil maintenance cover. Remove the oil filler cap and oil drain plug to drain the oil. Install the oil drain plug, and tighten it securely. Refill with the recommended oil (see page ) and check the oil level.
  • Page 46 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Do not use gasoline or low flash point solvents for cleaning. They are flammable and explosive under certain conditions.
  • Page 47 Soak the foam element in clean engine oil and squeeze out the excess oil. The engine will smoke during initial startup if too much oil is left in the foam element. Reinstall the foam element to the air cleaner cover. Paper element: If the paper element is dirty, replace it with a new one.
  • Page 48 FUEL SEDIMENT CUP SERVICE Gasoline is extremely flammable and is explosive under certain conditions. Do not smoke or allow flames or sparks in the area. The filter prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the filter should be cleaned.
  • Page 49 Remove the sediment cup by turning it counterclockwise. Clean the sediment cup, rubber gasket, and filter in nonflammable or high flash point solvent. Reassemble the filter, rubber gasket, and sediment cup. Tighten securely. Reinstall the air cleaner base, and connect the breather gas hose with the air cleaner base.
  • Page 50 SPARK PLUG SERVICE RECOMMENDED SPARK PLUG: BPR5ES (NGK) W16EPR-U (DENSO) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. Open the left side maintenance cover. Loosen the cover screw and remove the spark plug inspection cover. SPARK PLUG INSPECTION COVER COVER SCREW Remove the spark plug cap.
  • Page 51 Visually inspect the spark plug. Discard it if the insulator is cracked, chipped, or fouled. Clean the spark plug with a wire brush if it is to be reused. Measure the plug gap with a feeler gauge. Correct as necessary by carefully bending the side electrode. The gap should be: 0.7 0.8 mm (0.028 0.031 in) PLUG GAP...
  • Page 52 FUSE REPLACEMENT (EU30is only) If the fuse is blown, the starter motor will not work until it is replaced. Turn the engine switch to the OFF position. Remove the four 6 mm cap nuts and the front cover. FRONT COVER 6 mm CAP NUTS Remove the fuse holder cover and replace the fuse.
  • Page 53 BATTERY REMOVAL/INSTALLATION (EU30is only) Batteries produce explosive gases: If ignited, and explosion can cause serious injury or blindness. Provide adequate ventilation when charging. CHEMICAL HAZARD: Battery electrolyte contains sulfuric acid. Contact with eyes or skin, even through clothing, may cause severe burns.
  • Page 54 Installation: Make sure that the engine switch is turned OFF. Connect the battery positive ( ) cable to the battery positive ( ) terminal, then the battery negative ( ) cable to the battery negative ( ) terminal. Tighten the bolts and nuts securely. Install the battery holder band.
  • Page 55: Transporting/Storage

    TRANSPORTING/STORAGE To prevent fuel spillage when transporting or during temporary storage, the generator should be secured upright in its normal operating position, with the engine switch OFF. The fuel valve lever should be turned OFF. When transporting the generator: Do not overfill the tank. Do not operate the generator while it is on a vehicle.
  • Page 56 Once a month, recharge the battery. (EU30is only) Change the engine oil. Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. Slowly pull the starter grip until resistance is felt.
  • Page 57: Troubleshooting

    To check: If the engine still Turn off the fuel valve does not start, lever and loosen the take the drain screw. generator to an Turn on the fuel valve authorized lever. Fuel should flow Honda dealer. from the drain.
  • Page 58 (Except U type) protector ON. Is the output indicator ON? Is the Overload Take the indicator ON? generator to an authorized Honda dealer. Check the Take the electrical NO DEFECTS generator to an appliance or authorized equipment for Honda dealer.
  • Page 59: Specifications

    SPECIFICATIONS Dimensions and Weight Model EU26i Description code EZGE Length (Stand type) 658 mm (25.9 in) (Wheel type) 658 mm (25.9 in) Width (Stand type) 447 mm (17.6 in) (Wheel type) 482 mm (19.0 in) Height (Stand type) 558 mm (22.0 in) (Wheel type) 570 mm (22.4 in)
  • Page 60 Noise Model EU26i Type F, G, GW, B Sound pressure level (Lp ) 75 dB According to 98/37/EC Microphone point CONTROL PANEL Center 1.60 m 1.0 m Guaranteed sound power level 90 dB ) Tested by 2000/14/EC ‘‘the figures quoted are emission levels and are not necessarily safe working levels.
  • Page 61 Dimensions and Weight Model EU30is Description code EZGF Length (Stand type) 658 mm (25.9 in) (Wheel type) 658 mm (25.9 in) Width (Stand type) 447 mm (17.6 in) (Wheel type) 482 mm (19.0 in) Height (Stand type) 558 mm (22.0 in) (Wheel type) 570 mm (22.4 in) Dry weight...
  • Page 62 Noise Model EU30is Type F, G, GW, B Sound pressure level (Lp ) 76 dB According to 98/37/EC Microphone point CONTROL PANEL Center 1.60 m 1.0 m Guaranteed sound power level 91 dB ) Tested by 2000/14/EC ‘‘the figures quoted are emission levels and are not necessarily safe working levels.
  • Page 63: Wiring Diagram

    WIRING DIAGRAM ACCP AC Circuit Protector ACNF AC Noise Filter ACOR AC Output Receptacle Battery Charge Winding Control Panel Block Control Panel Ground DC Diode DCNF DC Noise Filter DCCP DC Circuit Protector DC Winding DCOR DC Output Receptacle EcoSw Eco Throttle Switch Engine Block Engine Ground...
  • Page 64 BLACK YELLOW BLUE GREEN WHITE BROWN LIGHT GREEN GRAY LIGHT BLUE ORANGE PINK ENGINE SWITCH EU26i EU30is START ECOTHROTTLE SWITCH ECOTHROTTLE...
  • Page 65 EU26i: G, GW, B, F...
  • Page 66 EU30is: G, GW, B, F...
  • Page 67 EU30is: U...
  • Page 68 RECEPTACLE Shape Type G, GW...
  • Page 69: Major Honda Distributor Addresses

    MAJOR Honda DISTRIBUTOR ADDRESSES For further information, please contact Honda Customer Information Centre at the following address or telephone number: AUSTRIA CROATIA FINLAND Honda Motor Europe (North) Hongoldonia d.o.o. OY Brandt AB. Hondastraße 1 Jelkovecka Cesta 5 Tuupakantie 7B 2351 Wiener Neudorf...
  • Page 70 PORTUGAL SLOVAKIA REPUBLIC JP Motor Ltd Honda Portugal, S.A. Kubiliaus str. 6 Abrunheira Honda Slovakia, spol. s r.o. 08234 Vilnius 2714-506 Sintra Prievozská 6 - 821 09 Tel. : 370 5 276 5259 Tel. : 351 21 915 53 33...
  • Page 71 SLOVENIA UKRAINE AS Domzale Moto Center D.O. Honda Ukraine LLC 101 Volodymyrska Str. - Build. 2 Blatnica 3A Kiev 01033 1236 Trzin Tel. : 380 44 390 1414 Tel. : 386 1 562 22 42 Fax : 380 44 390 1410...