Electric motor kit
Hide thumbs Also See for GH 200:

Advertisement

Improper installation or alteration of the grounding plug
will result in a risk of electric shock, fire or explosion that
could cause serious injury or death.
The sprayer must be grounded. Grounding reduces the
risk of static and electric shock by providing an escape
wire for the electrical current due to static build up or in
the event of a short circuit.
Fig. 1. 120 Vac: requires a 120 Vac, 60 Hz, 20A
(15A for 248949) circuit with a grounding receptacle
(A). 230 Vac: requires a 230 Vac, 50 Hz, 13A circuit
with a grounding receptacle (A). Never use an outlet
that is not grounded (A) or an adapter.
F
. 1
IG
Models:
248559, 248560, 248561,248565, 248566, 248568
Fig. 2. Align pulley (4) approximately 0.36 in. from end of
electric motor shaft.
F
. 2
IG
310812F
Grounding
Do not use sprayer if electric cord has a damaged
ground prong (B). Only use an extension cord with
an undamged 3-prong plug.
Recommended extension cord lengths:
25 ft (7.6 m) 18 AWG
50 ft (15.2 m) 16 AWG
100 ft (30.5 m) 14 AWG
150 ft (45.7 m) 12 AWG
Smaller gauge or longer cords may reduce
sprayer performance.
If the power cord or plug is damaged, replace with
the appropriate cord listed in the Parts List.
Pulley Placement
Models:
233940, 233941, 233942, 233943
Fig. 3. Align pulley (4) at end of electric motor shaft.
F
. 3
IG
Grounding
3