Vehicle Will Not Charge
Has the Key switch been turned to
the LOCK position?
NO
YES
Are the 24V Voltage Isolator
switches ON and the Battery Pod
MSDs installed?
YES
NO
Is the Battery Charger Cable
correctly connected?
NO
YES
Are the Circuit Breaker LED lights
illuminated?
YES
NO
Is the AC charging station ON?
NO
YES
Is infrastructure power ON?
YES
NO
Check 24V Isolator
Switches Refer to
Figure 5.1
Install MSDs,
Refer to Figure 5.2
Check breakers in the
circuit breaker box,
Refer to Figure 5.9
Check infrastructure
electrical source