Download Print this page

Ericsson 1341-B Service Manual page 11

Handheld

Advertisement

Item 3
RF Output Power
Purpose: Check and, if necessary, adjustment of the RF output power levels.
Input signal: None.
Test method: Radio test set in TX mode, measured with a RF power meter.
Test program settings:
Measurement point: Output power at the antenna connector.
Values:
Tolerance: +2/-4 dBm at all power levels.
Procedure: If the transmitter output power is not within the above stated lim-
its use test option 5 and press either 0, 1 or 2 to select power table. The dis-
play will show selected table, power level and current voltage value. Use the
and
or M & # to step to the next power level. When all power levels in table 0
have been adjusted, table 1 will automatically be selected, starting with power
level 2. Press CLR when adjustment is ready to return to menu 0, "Test Input".
1:1
2:2-7 TX Power Level 2 down to 7.
PL
Output Power
2
26.5 dBm
3
22.5 dBm
4
18.5 dBm
5
14.5 dBm
6
10.5 dBm
7
6.5 dBm
buttons to adjust the output power. Press M & S to store the value
SERVICE: Telephone
Channel selection
11

Advertisement