2.

HANDLING PRECAUTIONS

This instrument has been already tested thoroughly at
the factory. When the instrument is delivered, please
check externals and make sure that no damage
occurred during transportation.
In this chapter, handling precautions are described.
Please read this chapter thoroughly at first. And please
refer to the relative matter about other ones.
If you have any problems or questions, please make
contact with Yokogawa sales office.
2.1 Checking Model and
Specifications
The model and specifications are shown on the Data
Plate. Please confirm the specifications between the
instrument that was delivered and the purchase order
(refer to the chapter 5. Outline).
Please let us know Model and Serial No. when making
contact with Yokogawa sales office.
MAGNETIC
FLOW DETECTOR
AM
Figure 2.1
Data Plate

2.2 Accessories

When the instrument is delivered, please make sure
that the following accessories are in the package.
• Centering device 1-set (for wafer type)
• Hexagonal wrench 1-piece (for hazardous duty type
except JIS flameproof type)
• Hexagonal wrench 2-piece (only for JIS flameproof
type)
mm
L
H
Made in Japan
F0201.EPS

2.3 Storage Precautions

In case the instrument is expected to be stored over a
long term, please give attention to the followings;
• The instrument should be stored in its original
packing condition.
• The storage location should be selected according to
the following conditions:
1) The location where it is not exposed to rain or
water.
2) The location where there is few vibration or
shock.
3) Temperature and humidity should be:
Temperature: –30 to 60˚C (–22 to 140˚F)
Humidity:
Preferable ambient temperature and humidity
are 25˚C(77˚F) and about 65% RH.
2.4 Installation Location
Precautions
Please select the installation location considering the
following items to ensure long term stable operation of
the flow tube.
• Ambient Temperature:
Please avoid to install the instrument at the location
where temperature changes continuously. If the
location receives radiant heat from the plant, provide
heat insulation or improve ventilation.
• Atmospheric Condition:
Please avoid to install the instrument in an corrosive
atmosphere. In case of installing in the corrosive
atmosphere, please keep ventilating sufficiently and
prevent rain from entering the conduit.
• Vibration or shock:
Please avoid to install the instrument at the location
where there is heavy vibration or shock.
2.5 Terminal Box Reori-
entation Precautions
Please do not change the terminal box orientation at
the customer's site. If the terminal box reorientation is
required, please contact Yokogawa office or service
center.
2-1
2. HANDLING PRECAUTIONS
5 to 80% RH (no condensation)
IM 1E6D0-01E