Model Number Nomenclature And Dimensions; Rated Indoor Airflow - Bryant Legacy 549J 12 Series Installation Instructions Manual

Single package rooftop heat pump with puron (r-410a) refrigerant
Table of Contents

Advertisement

Understand the signal words DANGER, WARNING,
CAUTION, and NOTE. These words are used with the safety-
alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices,
which may result in minor personal injury or product and
property damage. NOTE is used to highlight suggestions
which will result in enhanced installation, reliability, or
operation.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning will result in personal injury
or death.
Before performing service or maintenance operations on
unit, turn off main power switch to unit and install lock(s)
and lockout tag(s). Ensure electrical service to rooftop unit
agrees with voltage and amperage listed on the unit rating
plate. Unit may have more than one power switch.
WARNING
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this warning could cause personal injury,
death and/or equipment damage.
R-410A refrigerant systems operate at higher pressures
than standard R-22 systems. Do not use R-22 service
equipment
or
components
equipment.
DANGER
on
R-410A
refrigerant
PERSONAL INJURY AND ENVIRONMENTAL
HAZARD
Failure to follow this warning could cause personal injury
or death.
Relieve pressure and recover all refrigerant before system
repair or final unit disposal.
Wear safety glasses and gloves when handling refrigerants.
Keep torches and other ignition sources away from refriger-
ants and oils.
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing, safety glasses and
gloves when handling parts and servicing air conditioning
equipment.
MODEL NUMBER NOMENCLATURE AND
DIMENSIONS
See Fig. 1 for 549J model number nomenclature. See Fig. 2 for
unit dimensional drawings. Figure 3 shows service clearance
dimensions.

Rated Indoor Airflow

Table 1 lists the rated indoor airflow used for the AHRI effi-
ciency rating for the units covered in this document.
Table 1 — Rated Indoor Airflow
MODEL NUMBER
549J*12
2
WARNING
CAUTION
RATED INDOOR AIRFLOW
(CFM)
4000

Advertisement

Table of Contents
loading

Table of Contents