Balluff BNI IOL-302-002-Z046 User Manual

Balluff BNI IOL-302-002-Z046 User Manual

Io-link 1.1 sensor/actuator hub with extension port
Hide thumbs Also See for BNI IOL-302-002-Z046:
Table of Contents

Advertisement

Quick Links

BNI IOL-302-002-Z046
IO-Link 1.1 sensor/actuator hub
with extension port
User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BNI IOL-302-002-Z046

  • Page 1 BNI IOL-302-002-Z046 IO-Link 1.1 sensor/actuator hub with extension port User's Guide...
  • Page 2: Table Of Contents

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Contents General 1.1. Structure of the Manual 1.2. Typographical Conventions Enumerations Actions Syntax Cross-references 1.3. Symbols 1.4. Abbreviations Safety 2.1. Intended use 2.2. Installation and Startup 2.3. General Safety Notes 2.4. Resistance to Aggressive Substances...
  • Page 3 Resetting to Factory Settings Technical Data 9.1. Dimensions 9.2. Mechanical Data 9.3. Electrical Data 9.4. Operating conditions Function indicators 10.1. Function indicators LED indicator module status Digital LED indicators for inputs/outputs Extension port Appendix 11.1. Type code 11.2. Ordering information www.balluff.com...
  • Page 4: General

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 General 1.1. Structure of the The manual is organized so that the sections build on one another. Manual Chapter 2: Basic Safety Information. …….. 1.2. Typographical The following typographical conventions are used in this manual.
  • Page 5: Safety

    Before maintenance, disconnect the device from the power supply. Note In the interests of product improvement, Balluff GmbH reserves the right to change the technical data of the product and the content of this manual at any time without notice.
  • Page 6: First Steps

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 First Steps 3.1. Connection Overview Figure 3-1: Connection overview BNI IOL-302-002-Z046 1 Ground connection 12 Port 15, extension port 2 Mounting hole 13 Pin/Port LED: signal status 3 Status LED: communication 14 Port 14...
  • Page 7: Mechanical Connection

    The BNI IOL modules are attached using 2 max. M4 screws and 2 washers. Connection 3.3. Electrical The BNI IOL-302-002-Z046 modules do not require a separate supply voltage connection. Connection Supply voltage is provided via the IO-Link interface and the higher-level IO-Link master module.
  • Page 8: Connecting The Sensor Hub

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 First Steps  Connect ground conductor to the functional ground connection, if available. Connecting the  Connect the incoming IO-Link cable to the sensor hub. sensor hub Note A standardized sensor cable is used to connect to the higher-level to the IO-Link master module.
  • Page 9: General Configuration

    4.1. Extension port The BNI IOL-302-002-Z046 module gives you the ability to use the No. 15 slot in various ways. The standard setting is use as a digital I/O slot, where Pin 4 can be used as a digital input or output.
  • Page 10: Configuration: "Extension Off

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: "Extension Off" 5.1. IO-Link data BNI IOL-302-002-Z046 Extension off Transmission rate COM2 (38.4 kBaud) Minimum cycle time 4.0 ms Process data length 2 byte input, 2 byte output 5.2. Process Byte Data/Input Data 5.3.
  • Page 11: Parameter Data / Demand Data

    Subin Vendor ID 2 bytes 0378 Device ID 3 bytes 05 0D 20 Vendor Name BALLUFF Vendor text www.balluff.com Product BNI IOL-302-002-Z046 Name Product ID BNI00AU Product text M8 sensor/actuator hub Serial number 16 bytes 0hex Hardware revision Firmware revision...
  • Page 12: Inversion Of The Inputs (40Hex)

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: "Extension Off" Inversion of the Byte inputs (40 Subin Inversion of port (x): 0 – Normal 1 - Inverted. Configuration Byte inputs/outputs Subin Direction of port (x): 0 – Input 1 – Output Safe state of The safe state parameter makes it possible to configure the outputs in case of a fault.
  • Page 13 Configuration: "Extension Off" Byte Sub- Index Value Output state Output is 0V Output is 24V Current status is maintained Not permitted www.balluff.com...
  • Page 14: Voltage Monitoring 44Hex

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: "Extension Off" Voltage Byte monitoring Sub- Index Byte Sub- Index Monitoring the Byte outputs (45 Sub- Index Actuator Byte warning (46 Sub- Index www.balluff.com...
  • Page 15: Configuration: Extanded With Bni Iol-104-002-Z046

    Configuration: Extanded with BNI IOL-104-002-Z046 6.1. IO-Link data BNI IOL-302-002-Z046 extanded with BNI IOL-104-002-Z046 Transmission rate COM2 (38.4 kBaud) Minimum cycle time 4.5 ms Process data length 4 byte input, 2 byte output 6.2. Process Byte Data/Input Data Byte Extension port...
  • Page 16: Process Data/Output Data

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: Extanded with BNI IOL-104-002-Z046 6.3. Process Data/ Byte Output Data www.balluff.com...
  • Page 17: Parameter Data / Demand Data

    Subin Vendor ID 2 bytes 0378 Device ID 3 bytes 05 0D 21 Vendor Name BALLUFF Vendor text www.balluff.com BNI IOL-302-002-Z046 Product with BNI IOL-104-002- Name Z046 BNI00AU Product ID with BNI00AY Sensor/Actor hub M8 Product text extended with Sensor...
  • Page 18: Inversion Of The Inputs (40Hex)

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: Extanded with BNI IOL-104-002-Z046 Inversion of Byte the inputs Sub- Index Byte Sub- Index Extension port Inversion of port (x): 0 - Normal 1 - Inverted Configuration Byte inputs/outputs Subin Direction of port (x): 0 –...
  • Page 19: Safe State Of Outputs 42Hex

    The following statuses can be configured for each pin. Safe state of Byte the outputs on Pin 4 42 Sub- Index Byte Sub- Index Value Output state Output is 0V Output is 24V Current status is maintained Not permitted www.balluff.com...
  • Page 20: Voltage Monitoring 44Hex

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Configuration: Extanded with BNI IOL-104-002-Z046 Voltage Byte monitoring Sub- Index Byte Sub- Index Byte Sub- Index Extension port www.balluff.com...
  • Page 21: Monitoring The Outputs (45Hex)

    The serial number has a default value of 16x00 hex. serial number In order to use the "Identity" master validation mode, a serial number can be set using this parameter. This prevents a device from connecting to the wrong master port. www.balluff.com...
  • Page 22: Diagnostics

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Diagnostics 7.1. Errors Error Code Description 0x8011 Index not available 0x8012 Subindex not available 0x8023 Access Denied 0x8033 Parameter length overrun 0x8034 Parameter length underrun 0x8035 Function not available 7.2. Events IO-Link Revision 1.0...
  • Page 23: Io-Link Functions

    The factory settings on the device can be restored by carrying out the "restore factory settings" Factory system command. Settings 0x82 must be written to Index 2 Subindex 0 for the command. The extension port setting is not reset in this process. www.balluff.com...
  • Page 24: Technical Data

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Technical Data 9.1. Dimensions 9.2. Mechanical Housing material Die-cast zinc, matte nickel-plated Data IO-Link port M12, A-coded, plug Input/output port 16x M8, female Weight 406 g Dimensions (L×W×H) 30 x 220 x 32.8 (mm) 9.3.
  • Page 25: Function Indicators

    Function indicators 10.1. Function indicators COM/ US/UA LED indicator Status Function module status Green Communication error, US and UA OK Green, flashing Communication OK, US and UA OK COM/ US/UA Undervoltage actuator Red, flashing quickly Undervoltage module www.balluff.com...
  • Page 26: Digital Led Indicators For Inputs/Outputs

    Balluff Network Interface / IO-Link BNI IOL-302-002-Z046 Function indicators Digital LED LED 0, input/output Pin 4 indicators for inputs/outputs Status Function Input/output signal = 0 Yellow Input/output signal = 1 Sensor power supply short-circuit, Actuator warning Actuator short-circuit Extension port The table is valid if the extension port is active.
  • Page 27: Appendix

    Appendix 11.1. Type code BNI IOL-302-002-Z046 Balluff Network Interface IO-Link interface Functions 302 = 16 inputs/outputs Variants 002 = with IO-Link 1.1 extension port Mechanical configuration Z046 = Die-cast zinc, matte nickel plated Bus connection: 1x M12x1 external threads, I/O ports: 16 x M8x1, internal threads 11.2.
  • Page 28 Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 www.balluff.com balluff@balluff.de...