• Mode, Real-time or Demo,
• Capture Light, which flashes blue during a
screen capture, and
• Capture Status, showing the screen capture
schedule and remaining hard disk space.
• Cursor Position. Depending on which display is
active, the cursor position will include range
(R), bearing (B, negative to port, positive to
starboard) and/or depth (D). When the cursor is
outside of a data display area, the position box
displays the current range and gain settings (e.g.
Rnge=25ft; Gain=20).
Operating Modes
PC/180 operates in one of two modes: Demo and
Real-time. If all components have been installed, all
cables are connected and the Acoustic Interface Mod-
ule is on when you start the software, PC/180 will
immediately begin to collect and display data in
Real-time Mode. If PC/180 does not find the Acous-
tic Interface Module, the software will initiate Demo
Mode. Use the File Menu to switch between Demo
Mode and Real-time Mode.
Demo Mode
In Demo Mode, PC/180 will continuously display the
demo data that was installed with the software. PC/
180 will look for the demo data in a folder called
'Data' in the PC/180 program folder. If the program
does not find the demo data, the display window will
remain blank.
With the exception of Gain adjustments, all PC/180
features are fully functional in Demo Mode. How-
ever, when running in Demo mode, be sure the range
is on the lowest setting. Higher range settings will
simply compress the data in the display.
Real-time Mode
When Real-time Mode is selected, PC/180 will at-
tempt to find the Acoustic Interface Module. If the
attempt is unsuccessful, PC/180 will prompt you to
return to Demo Mode.
Status Bar
Ping Light
Status Message
Cursor Position
Range
Bearing
21
Capture Light
Mode
Capture Status
Depth