Power On/Off Switch and Status Indicator Operation
Normal Operation
Power up the IPC
Shut down the IPC
Sleep Mode
Forced Shut down
†
The ring LED displays solid red to indicate a fault, including Overtemp condition.
IPC Status Indicators Operation
Ethernet Port LEDs Operation
Each Ethernet port has two LED indicators, ACTIVITY and LINK.
ACTIVITY
LINK
GFK-2785C
†
Press and hold the button for at least ½ second.
If powering up from a no-power state, the ring LED blinks blue while the IPC is
booting and is solid green when the IPC is up and running.
For ICRXIBN7x000A-CA or earlier only: If the system has been shut down, but
power has not been cycled, the ring LED immediately turns solid green.
For all other versions the ring LED blinks blue for 40 seconds before changing to
solid green.
Press and hold the button briefly (between 100ms and 4 seconds).
The ring LED stays green while the IPC is shutting down and then turns off when
the IPC is powered down.
The default BIOS settings when shipped from the factory are:
The default settings send IPC to sleep state S1.
ICRXIBN7x000A:
ICRXIBN7x001A:
Caution: Use this option only if the operating system is non-responsive:
Press the button for at least 4 seconds.
The ring LED turns off.
Indicator
White, blinking
SATA Drive Status
Red, solid
Overtemp
LED
Introduction
"Enable Hibernation" is disabled
ACPI Sleep State is "S1 (CPU Stop Clock)"
The ring LED stays green while the IPC is in Sleep State S1.
The ring LED turns off while the IPC is in Sleep State S3
The ring LED stays green while the IPC is in Sleep State S1.
The ring LED fades blue while the IPC is in Sleep State S3.
State
Read/write access on SATA drive.
The IPC's internal temperature has exceeded the
maximum allowable value.
To recover, let the IPC cool, then press the Power On/Off
switch.
LED State
Blinking, Green
On, Green
PACSystems* RXi Box IPC
Action
Description
Operating State
Traffic is detected at the port.
The link is operational.
5