Specifications; Printing Specifications; Memory/Communications Specifications - Intermec EasyCoder PL4 User Manual

Intermec easycoder pl4: user guide
Hide thumbs Also See for EasyCoder PL4:
Table of Contents

Advertisement

Note: If you do not press the Feed button within 3
seconds, the printer prints "Dump mode not entered" and
resumes normal operation.
3
At this point, the printer is in Dump mode and prints the
ASCII hex codes of any data sent to it and their text
representation (or [.] if not a printable character).
Additionally, a file with a .DMP extension containing the ASCII
information is created and stored in the printer's memory. You
can view, clone, or delete the file using the Intermec PLUS
application.
To exit Communications Diagnostics mode and return the printer to
normal operations
1 Turn the printer off.
2 Wait 5 seconds.
3 Turn the printer on.

Specifications

Printing Specifications

Print density
Print width
Print speed
Printhead life, calculated
Distance from print element to
top of form

Memory/Communications Specifications

Flash memory
SRAM memory
Standard
communications
58
8 dots/mm (203 dots/inch)
Up to 103.8 mm (4.09 inches)
76.2 mm (3 inches) per second
50 km (1,964,160 inches) nominal
14.5 mm (0.571 inch) or 116 dots
2 MB flash (standard)
2 MB SRAM (standard)
Configurable baud rate (from 9600 to 115.2 Kbps),
parity and data bits. The highest baud rate with
consistent results is 38.4 Kbps.
Software (XON/XOFF) or hardware (DTR/STR)
communication handshake protocols.