Chapter 7 — Commands

SA - Setup Adjust

Purpose:
Syntax:
Remarks:
108
This command is used to control the activation and storage of
setup commands and values.
SAp
1
.
SA Command Parameter Descriptions
Parameter
Description
p
Setup adjust value:
1
0 = All commands remain active and values are
saved when changed. The printer uses stored
setup values (default).
1 = All setup parameters are locked and
commands are ignored. The printer uses only
previously stored setup values.
2 = All setup commands within forms are ignored.
The SA command affects the following setup commands: R, r, D,
j, J, q, Q, S, Z, and SPC. The current SA value is stored in Flash
memory and printed on the test label.
Example:
This example shows how to ignore all setup commands within a
form.
SA2
ESim for the PC4 and PF8 Printer Programmer's Reference Manual