Nailing Flanges; Facing And Mantel - Superior Fireplaces WCT4920 Installation And Operation Instruction Manual

Table of Contents

Advertisement

Nailing Flanges

FLOOR: Four floor nailing flanges are provided
to secure the fireplace to the floor (see Figure
13). Bend the nailing flanges down so that each
flange is flush with the floor, then using nails
or screws, secure the fireplace to the floor (2
places each side). The heads of the screws or
nails must be large enough to completely cover
the holes in the nailing flanges.
SIDES: Secure the sides of the fireplace to the
side framing using the side nailing flange as-
semblies shown in Figure 14.
FLOOR NAILING FLANGES
Fireplace Side
Nailing Flange
(2 places each side)
Figure 13
SIDE NAILING FLANGES
Side Nailing Flanges
(2 places)
Figure 14
14
Mantel and Facing
Any mantel must be constructed of non-combustible material.
Non-
Combustible
Mantel
Rock Board
or Other
Noncombustible
Facing
Figure 15
Unbend to floor
and nail/screw
Figure 16A
NOTE: Upper Convection Cover (included with Cleanface kit) is required
for the Cleanface and must be installed prior to facing material installation.
Figure 16C
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Mantel and Facing (Side View)
Drywall
2 x 3 Min.
(51mm x 76mm)
Adjustable
Stand-Offs
Only non-combustible mate-
rial should be superposed or
projecting over the front of
the fireplace.
56"
(1422mm)
Min.
Upper Convection Cover
NOTE: Top, bottom, and side guide marks on the front of the fireplace provide facing limits
when using materials greater than 1" thick that cannot extend behind the facade. These act as
a guide when facing materials are brought to the perimieter of the façade. See Figure 12C for
examples. Inner marks are for Clean Face and outer marks for Louvered Facades.
NOTE: Do not bring facing materials greater that 1" thick within these marks!
Drywall
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
Rock Board
.. . ..
.. . ..
Adjustable
.. . ..
or Other
.. . ..
Stand-Offs
.. . ..
.. . ..
.. . ..
.. . ..
(see Figures 12 & 17)
.. . ..
.. . ..
.. . ..
Noncombustible
.. . ..
.. . ..
Facing
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
.. . ..
..
Drywall
2 x 3 Min.
Adjustable
Standoffs
Noncombustible Facing
Rock Board or Other
Figure 16B
Cleanface
Arched and
Square
Lovered Facade
NOTE: Guide
marks only
apply to facing
materials greater
than 1" thick that
will be brought
to perimeter of
facade.
Cleanface
Arched and
Square
Lovered Facade

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wct4920ws