Quartz Flood Light - FL Series
INSTALLATION INSTRUCTIONS
Lamp Type: Tungsten Halogen 150 Watt
Model: FL150Q
IMPORTANT:
ELECTRICAL REQUIREMENTS
A qualified electrician should complete all required wiring. This fixture is for use with 120V AC only and must be
properly grounded for safety. A mounting suitable for outdoor use and rated for wet locations is required. Follow all
applicable electrical codes and regulations.
WARNING: Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING: Fire hazard
USE MIN 60ºC SUPPLY CONDUCTORS.
CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.
Lamp and housing become very hot during use.
Ensure free air circulation around unit to dissipate heat.
Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.
Avoid locations where humans or animals might accidentally touch fixture.
WARNING: Explosion hazard
Never operate light without securing the lens. When light is operating, the gas in the lamp is at high pressure.
Never operate light if the fixture lens is broken or missing.
WARNING: Explosion hazard
Wear safety glasses and gloves when handling lamp. Halogen lamp is pressurized and could explode if broken.
Do not handle lamp with bare hands.
MOUNTING & WIRING
1. Screw the threaded mounting arm of the fixture into 1/2" NPS mounting hole on mounting device.
Tighten locknut to secure fixture. (See Fixture 1)
CAUTION:
Mount the fixture so lamp is horizontal to prolong lamp life. (See figure 2)
Figure 1
FOR OUTDOOR USE ONLY
NOT FOR USE IN HAZARDOUS ATMOSPHERES
Read instruction sheet carefully before installing fixture.
Retain instructions for future reference.
Locknut
Mounting
Arm Bolt
Hinge
Install with lamp horizontal
Screw