3
SPECIFICATIONS AND UNPACKING
• Frequency coverage (MHz):
U.S.A.
Europe
* Specifications guaranteed 0.5–1300 MHz only.
• Receive system
• Mode
• Frequency stability
• Frequency resolution
• Power supply
requirement
• Current drain (at 13.8 V DC):
Power ON (PC power OFF)
Max. audio
Standby (squelched)
• Usable temp. range
• Intermediate frequencies:
1st
2nd
3rd
11
000.010000–823.999999*
849.000001–868.999999
894.000001–1300.000000
000.010000–1300.000000*
: Triple superheterodyne
: WFM, FM, AM, SSB, CW
: ± 3 ppm at 1300 MHz
(0°C to +50°C; 32°F to +122°F)
: 1 Hz (minimum)
: 13.8 V DC ±15 % for receiver
unit; or, supplied AC adapter
(negative ground)
0.1 A
0.7 A
0.6 A
: 0°C to +50°C; +32°F to +122°F
266.7 MHz
10.7 MHz
450 kHz (except WFM)
• Receive sensitivity (typical)*:
Frequency
SSB/CW
(MHz)
(10 dB S/N)
0.5–1.799999
0.56 µV
1.8–27.99999
0.28 µV
28–29.99999
30–49.99999
0.35 µV
50–699.99999
0.2 µV
700–1300
0.25 µV
* When 230 kHz (for WFM), 15 kHz (for FM), 6 kHz (for AM) and
2.8 kHz (for SSB/CW) passband widths are selected.
• Squelch sensitivity (threshold):
Frequency
SSB/CW
(MHz)
0.5–1.799999
14 µV
1.8–27.99999
28–29.99999
7.1 µV
30–49.99999
50–699.99999
5.6 µV
700–1300
7.1 µV
AM
FM
WFM
(10 dB S/N)
(12 dB SINAD)
(12 dB SINAD)
2.5 µV
1.4 µV
0.5 µV
1.8 µV
1.0 µV
0.32 µV
0.79 µV
1.3 µV
0.4 µV
1.0 µV
AM
FM
WFM
1.8 µV
0.89 µV
0.63 µV
0.71 µV
0.5 µV
5.6 µV
0.89 µV
0.63 µV
7.1 µV

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents