Fisher & Paykel SINGLE DISHDRAWER DD24STX6I Installation Manual

Fisher & Paykel SINGLE DISHDRAWER DD24STX6I Installation Manual

Advertisement

Quick Links

SINGLE DISHDRAWER™ DISHWASHER
INTEGRATED
DD24STX6I, DD24STX6HI
INSTALLATION GUIDE
US CA

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel SINGLE DISHDRAWER DD24STX6I

  • Page 1 SINGLE DISHDRAWER™ DISHWASHER INTEGRATED DD24STX6I, DD24STX6HI INSTALLATION GUIDE US CA...
  • Page 3: Safety And Warnings

    SAFETY AND WARNINGS  WARNING!  WARNING! Electric Shock Hazard Electric Shock Hazard Failure to follow this advice may result in Failure to follow this advice may result in electrical shock or death. electrical shock or death. • Fitting an integrated panel requires access to •...
  • Page 4 SAFETY AND WARNINGS WARNING! To reduce the risk of fire, injury to persons or damage when using the appliance, follow the important safety instructions listed below. Read all the guidance before using the appliance. Servicing Do not repair or replace any part of the appliance unless specifically recommended in this guide.
  • Page 5: Tools And Components

    TOOLS AND COMPONENTS PARTS SUPPLIED TOOLS REQUIRED Keep all packing materials until the unit has been inspected. Not supplied Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage. Fisher &...
  • Page 6: Product Dimensions

    PRODUCT DIMENSIONS PRODUCT DIMENSIONS INCHES A Overall height 17 7/8 B Overall width 23 9/16 C Overall depth* 22 1/2 D Depth of chassis 21 3/4 PLAN ISOMETRIC E Front panel depth** 5/8 – 13/16 16 – 20 F Max. drawer extension*** 20 3/4 *based on front panel thickness of 11/16"...
  • Page 7: Custom Panel Dimensions

    CUSTOM PANEL DIMENSIONS Material specifications Standard installation illustrated Maximum weight of panel must not exceed 19lb (9kg) (including handle) The panel should be adequately sealed to withstand moisture (122°F/50°C @ 80% RH). The back and sides of the panel should be completely sealed with a waterproof vapour barrier, such as polyurethane, to prevent damage.
  • Page 8: Standard Install

    CABINETRY STANDARD INSTALL ASSISTED OPENING INSTALL The assisted opening unit should be installed at the centre front of the cavity. For more information on assisted opening installations, refer to fisherpaykel.com Connections can Connections can be located in an be located in an adjacent cabinet adjacent cabinet on either side of...
  • Page 9 CLEARANCES PLAN CABINETRY CLEARANCES INCHES A Minimum clearance to adjacent cupboard door 1/16 B Minimum clearance to corner cupboard* *Access to both sides of the product will be required during installation. If access is not possible, the tubs may need to be removed for door installation and adjustments.
  • Page 10 PLUMBING & ELECTRICAL CONSIDERATIONS Hose and cord lengths Your services can be installed to either the left-hand or right-hand side of the product in an adjacent cabinet. Refer to 'Cabinetry preparation' for service access requirements. If the drain hoses supplied are not long enough to reach your services, you may purchase a Fisher &...
  • Page 11 HARD WIRING (OPTIONAL) You have the option to hard-wire your DishDrawer™ Dishwasher. To do this, we recommend to remove the supplied power cord and do the hardwiring installation as close to the cavity as possible. Lift the cover upwards until you are able to pull out towards you to remove.
  • Page 12 HARD-WIRING (OPTIONAL) Fix the Live and Neutral wires to the terminal block and the Earth wire to Ensure the hoses are not twisted before the chassis. refitting the drawer to the runners and clipping into place via both locking tabs. rear L rib hook...
  • Page 13: Service Access

    CABINETRY PREPARATION SERVICE ACCESS MOISTURE PROTECTION Service holes can be created on either side of the DishDrawer™ Dishwasher cavity as shown below. If the hole is created through wood, ensure the edges are smooth and rounded Align the supplied moisture protection If the hole is created through metal, ensure the supplied edge protector is fitted.
  • Page 14 EXTERNAL VENTING PREPARATION To prevent the build up of condensation produced by your DishDrawer™ Dishwasher, the external venting kit must be installed via one of the following options: THROUGH SAME CABINET THROUGH ADJACENT CABINET THROUGH FLOOR FRAMELESS FRAMED FRAMELESS FRAMED FRAMED &...
  • Page 15 FIT THE TRIM BRACKET PREPARE EXTERNAL VENTING We recommend fitting the trim bracket when installing your DishDrawer™ Dishwasher into a FIT THE VENTING HOSE TO THE DISHDRAWER™ DISHWASHER 18 7/8" (480mm) cavity to conceal any visible gap left between the countertop and chassis. Rotate the elbow at the rear of the Align the bracket to the chassis ensuring product to either the left or right...
  • Page 16 PUSH THE PRODUCT INTO THE CAVITY SECURE THE VENTING HOSE TO CABINETRY VENTING THROUGH CABINETRY If securing via bracket method: Secure all four side brackets to the DishDrawer™ Dishwasher, aligning bracket A with slot A and bracket B Unframed cabinetry with slot B.
  • Page 17 FIT THE CUSTOM PANEL Attach the Knock-to-Pause module to the panel as shown. Remove both side pins by twisting a Ensure the Knock-to-Pause module is quarter-turn towards the product front. oriented correctly and is not in contact Pull outwards to remove pin. with the bracket before securing.
  • Page 18 SECURE TO CABINETRY VIA BRACKETS (METHOD A) SECURE TO CABINETRY VIA DRAWER REMOVAL (METHOD B) Partially open the drawer and remove Open the drawer and press both locking the first screw cover from the tabs back to release. trim moulding. Lift the drawer off the runners and carefully set aside on a protected surface.
  • Page 19 PLUMBING & ELECTRICAL CONNECTION Ø38MM STANDPIPE INSTALLATION SINK TRAP/WASTE TEE INSTALLATION Install the drain hose support to the Install the drain hose support to the back wall, as close to the underside back wall, as close to the underside of the benchtop as possible. Refer to of the benchtop as possible.
  • Page 20 PLUMBING & ELECTRICAL CONNECTION SINGLE AIR GAP INSTALLATION Install your single Air Gap Kit to the benchtop like shown. Refer to ‘'Plumbing & electrical considerations' for minimum install heights. Thread wire clip on to the hose before securing the drain hose to the supplied hose joiner and fit to the Air Gap Kit.
  • Page 21: Installer Checklist

    INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER Electrical … Ensure all electrical tests have been conducted in accordance with local regulations. Installation … Check all parts are installed correctly and are secure. Test operation … Ensure DishDrawer™ Dishwasher is secure and drawer opens and closes freely with …...
  • Page 22: Troubleshooting

    TROUBLESHOOTING No program indicator lights up when the drawer is opened DISPLAY POSSIBLE CAUSE WHAT TO DO Ensure power is connected and is switched on. Water 1 Ensure the water supply is turned on. may need to be activated. Refer to your user guide for details. AUTO POWER-ON Supply fault.
  • Page 24 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2021. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue.

This manual is also suitable for:

Single dishdrawer dd24stx6hi

Table of Contents