4 UNPACK THE OVEN AND REMOVE THE DOOR(S)
Double models featured for illustration purposes only
A
5
ELECTRICAL CONNECTION TO JUNCTION BOX
Junction box location
for: undercounter
installation
Junction box
location for:
wall installation
Disconnect the power supply.
1
Remove the junction box cover.
2
3
Connect the oven cable to the junction box
through the U.L.-listed conduit connector.
Connect the two black wires together with
4
twist-on connectors.
Connect the two red wires together with
5
twist-on connectors.
Connect electrical connection according to
6
local codes and ordinances.
WOU130,WOSU30
Max. current draw:
19.4 A
Nameplate
Max. load:
4.6 kW
WOUD230,WODU30
Max. current draw:
38.3 A
Max. load:
9.2 kW
If local codes permit connecting the cabinet-
grounding conductor to the neutral white wire
in the junction box:
7a
Connect the factory-taped green and white oven
cable wires to the neutral (white) wire in the
junction box.
Replace the junction box cover.
8a
B
1
1
4
1
4
red wires
white and green
grounding oven
wires - factory
taped
OR
If local codes DO NOT PERMIT
connecting the cabinet-grounding
conductor to the neutral (white) wire in
junction box:
Separate the factory-taped green and white
7b
oven cable wires.
Connect the white oven cable wire to the
8b
neutral (white) wire in junction box.
Connect the green grounding oven cable
9b
wire to a grounded wire in the junction box.
Replace the junction box cover.
10b
3
cable from
cable from
red wires
power supply
power supply
box
black
wires
green grounding
oven wires
UL - listed conduit
UL - listed
- factory taped
connector
conduit connector
OR
If connecting to a four-wire electrical
system:
Separate the green and white oven cable wires.
7c
8c
Connect the white oven cable wire to the
neutral (white) wire in junction box.
Connect the green grounding oven cable wire
9c
to the (green) grounding wire in the junction
box.
Do not connect the green grounding wire to
the neutral (white) wire in junction box.
Replace the junction box cover.
10c
2
box
white
wires
black
wires

Advertisement