Fisher & Paykel OB24SCD Installation Manual page 7

Hide thumbs Also See for OB24SCD:
Table of Contents

Advertisement

Available languages

Available languages

Junction box
location for:
undercounter
installation
Junction box
location for:
wall installation
1 Disconnect the power supply.
2 Remove the junction box cover.
3 Connect the oven cable to the junction
box through the U.L.-listed conduit
connector.
4 Connect the two black wires together
with twist-on connectors.
5 Connect the two red wires together with
twist-on connectors.
6 Connect electrical connection according
to local codes and ordinances.
1 Position the oven in the prepared cavity.
IMPORTANT!
Do not lift the oven by the door handle.
2 Open the oven door fully.
3 Mark and pre-drill the screw holes.
4 Use the supplied screws to secure the oven to the cabinetry.
IMPORTANT!
Do not over-tighten the screws.
Do not seal the oven into the cabinetry with silicone or glue. This makes
future servicing difficult. Fisher & Paykel will not cover the costs of
removing the oven, or of damage caused by this removal.
8
ELECTRICAL CONNECTION TO JUNCTION BOX
Nameplate
All models
Voltage
Max. current Max.
draw
load
208V
16.6 A
3.5 kW
240V
19.4 A
4.6 kW
If local codes permit connecting the
cabinet-grounding conductor to the neutral
white wire in the junction box:
7AConnect the factory-taped green and white
oven cable wires to the neutral (white) wire
in the junction box.
8AReplace the junction box cover.
8
SECURE THE OVEN TO THE CABINETRY
red wires
white and green
grounding oven
wires - factory
taped
OR
If local codes DO NOT PERMIT
connecting the cabinet-grounding
conductor to the neutral (white) wire in
junction box:
7BSeparate the factory-taped green and
white oven cable wires.
8BConnect the white oven cable wire to
the neutral (white) wire in junction box.
9BConnect the green grounding oven cable
wire to a grounded wire in the junction
box.
!0BReplace the junction box cover.
Oven may vary
cable from
cable from
red wires
power supply
power supply
box
black
wires
green grounding
oven wires
UL - listed
UL - listed
- factory taped
conduit connector
conduit connector
OR
If connecting to a four-wire electrical
system:
7CSeparate the green and white oven cable
wires.
8CConnect the white oven cable wire to the
neutral (white) wire in junction box.
9CConnect the green grounding oven cable
wire to the (green) grounding wire in the
junction box.
Do not connect the green grounding wire to
the neutral (white) wire in junction box.
!0CReplace the junction box cover.
box
white
wires
black
wires
6

Advertisement

Table of Contents
loading

Table of Contents