Hussmann R3 Installation And Operation Manual

Hussmann R3 Installation And Operation Manual

Refrigerated service and/or prep with refrigerated self service front

Advertisement

R3, R3P
RefRigeRated SeRvice and/oR PReP
with RefRigeRated
Self SeRvice fRont
P/n igfP-R3, R3P-0608
INSTALLATION & OPERATION GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for Hussmann R3

  • Page 1 R3, R3P RefRigeRated SeRvice and/oR PReP with RefRigeRated Self SeRvice fRont P/n igfP-R3, R3P-0608 INSTALLATION & OPERATION GUIDE...
  • Page 2: Table Of Contents

    Product control The serial number and shipping date of all equipment has been recorded in Hussmann’s files for warranty and replacement part purposes. All correspondence pertaining to warranty or parts ordering must include the serial number of each piece of equipment involved, in order to provide the customer with the correct parts.
  • Page 3: Cut And Plan Views

    STUB UP 18" X 18" Service Prep / Self Service Case Scale = 1/2" " Prep Top Area " " " " R3 Options Sushi Service Top and Prep Areas With Two Shelf Self Service Options Self Contained Scale = 1/2"...
  • Page 4: Installation

    Secure the overhead structure by bolting the bracket, located inside behind lights. 9. Apply bead of silicone to top of bulkheads and slip on stainless steel bulkhead cap. Also apply silicone to seam between overhead light tubes. igfP-R3, R3P-0608...
  • Page 5: Corner Wedges

    Rev. 0608 10. Use finger to smooth silicone as thin as possible at masking tape on inside and outside of rear mullion (apply additional silicone if necessary). Remove tape applied on line #3. corner wedges Corner wedges are attached via front and rear camlocks. Use a 7mm allen wrench to turn the locks.
  • Page 6: Wrapping Boards Installation Instructions

    R3P-0608 installation (cont'd) wrapping Boards installation instructions Step : Measure 10 inches from top of the case. Step 1: Measure 6 inches from wrapping board end. note: line up 6 inch mark with 10 inch mark. Step 3: Use bracket center hole to align with cross mark.
  • Page 7 Rev. 0608 Step 7: Mount wrap board on top of bracket using a ¼” spacer to have a gap between rear wall and board. installation (cont'd) Step 6: Install upper support bracket Step 8: screw bracket into wrap board (screws provided -#8 X 1 ¼”) Installation Complete...
  • Page 8: Bumper Installation Instructions

    Step 4: As you insert the bumper into the channel with one hand, pull the bumper toward you with the other to open the inside lips. Slowly apply pressure by rolling the bumper into the track. igfP-R3, R3P-0608...
  • Page 9 Rev. 0608 Boston Series 2000 NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: Rigid top: do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 10 ● Set the uncoiled flexible vinyl at room temperature 24 hours prior to installation. ● Lubricate the inside of the vinyl with soapy water or silicone before installing. ● Over cut the flexible vinyl and compression fit. Adding the additional materials will compensate for stretching which occurs during installation. installation (cont'd) igfP-R3, R3P-0608...
  • Page 11 Rev. 0608 Boston 1000 Series NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: Rigid top: do not over cut. installation 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 12: Plumbing

    Defrost times should be as follows: OFF CYCLE - Defrost times should be as directed in the R3, R3P technical data sheet. The number of defrosts per day and the duration of the defrost cycle may be adjusted to meet conditions present at your location.
  • Page 13: Electronic Expansion Valve (Optional)

    TX Valve. Service case temperature control Temperature control in the upper section of the R3 with the Service Option is done by means of a thermostat and suction solenoid valve. This controls both temperature and humidity.
  • Page 14: Field Wiring And Serial Plate Amperage

    Hussmann cases were not designed to “heat up” or “cool down” product - but rather to maintain an item’s proper temperature for maximum shelf life. To achieve the protection required always: 1.
  • Page 15: Non-Glare Glass

    Hussmann recommends using a clean damp chamois, or a paper towel marketed as dust and abrasive free with 210 Plastic cleaner and Polish available by calling Sumner Labs at 1-800-542-8656.
  • Page 16: Electrical Wiring Diagrams

    R3 Prep R3-P-8-ReM R3-P-4-ReM walMaRt R3-P-6-ReM walMaRt R3 top only - cold R3to 2000 S/c toP onlY BloweR electrical wiring diagrams igfP-R3, R3P-0608 W0180047 W0180048 W0180049 W0180051 W1800167 W180017 W1800173 W0180101 W018010 W0180103 W0180105 W18001...
  • Page 17: Wiring Diagrams

    Rev. 0608 125-03-1131 F28T5-48" wiring diagrams WIRE LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK WHITE BLACK...
  • Page 18 125-03-1131 T5-36" FP21/830 125-03-1131 T5-36" FP21/830 wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST igfP-R3, R3P-0608 WHITE BLACK WHITE BLACK...
  • Page 19 Rev. 0608 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK WHITE BLACK...
  • Page 20 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST igfP-R3, R3P-0608 WHITE BLACK WHITE BLACK...
  • Page 21 Rev. 0608 225-01-3228 225-01-3228 SENSOR SENSOR 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (cont'd) BLACK WHITE BLACK WHITE BLACK LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK...
  • Page 22 R3P-0608 wiring diagrams (cont'd)
  • Page 23 Rev. 0608 wiring diagrams (cont'd) BLACK WHITE WHITE BLACK 125-03-1131 F28T5-48" LH3-120-L FULHAM 125-01-3266 BALLAST 125-03-1131 F28T5-48" WHITE BLACK...
  • Page 24 (cont'd) 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" 125-03-1128 F21T5-36" BLACK WHITE WHITE BLACK LH3-120-L FULHAM 125-01-3266 BALLAST LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK igfP-R3, R3P-0608...
  • Page 25 Rev. 0608 wiring diagrams (cont'd) WIRE LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK BLACK WHITE WHITE BLACK...
  • Page 26 (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST igfP-R3, R3P-0608 WHITE BLACK BLACK WHITE WHITE BLACK...
  • Page 27 Rev. 0608 wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST WHITE BLACK BLACK WHITE WHITE BLACK...
  • Page 28 125-03-1131 F28T5-48" 125-03-1131 F28T5-48" wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST igfP-R3, R3P-0608 WHITE BLACK BLACK WHITE WHITE BLACK...
  • Page 29 Rev. 0608 BLACK WHITE OPTIONAL 125-03-1131 FP28/835 LIGHT SHELF 125-03-1131 FP28/835 SECTION LIGHTING wiring diagrams (cont'd) LH3-120-L FULHAM 125-01-3266 BALLAST BLACK WHITE WHITE BLACK WHITE BLACK...
  • Page 30: Appendices

    They are based on confirmed field experience over many years. 1.1 The installer is responsible for following the installation instructions and recommendations provided by Hussmann for the installation of each individual type refrigerator. 1. Refrigeration piping should be sized according to the equipment manufacturer’s recommendations and installed in accordance with normal refrigeration practices.
  • Page 31: Appendix D. - Recommendations To User

    Does the system use the recommended compressor? appendix d. - Recommendations to User 1.0 Hussmann Corporation provides instructions and recommendations for proper periodic cleaning. The user will be responsible for such cleaning, including the cleaning of low temperature equipment within the compartment and the cooling coil area(s).
  • Page 32 Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling. for further technical information, please log on to http://www.hussmann.com/products/R3P.htm or http://www.hussmann.com/products/R3to.htm appendices (cont'd) d) Care must be taken when cross...
  • Page 33 The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. They can be found on a small metal plate on the unit. Please note them below for future reference. Model: SeRial nUMBeR: igfP-R3, R3P-0608...

This manual is also suitable for:

R3p

Table of Contents