LEVELING

Merchandisers must be installed level
to ensure proper operation of the
refrigeration system and to ensure
proper drainage of defrost water.
When leveling merchandisers, use a
carpenter's level as shown.
Metal leveling shims or wedges are
provided with each merchandiser for
use if needed.
NOTE: B
EGIN LINEUP LEVELING
FROM THE HIGHEST POINT OF THE
.
STORE FLOOR
Place shims under the rail and make
sure that they are positioned at a base
component (crossbar). This transfers
the weight directly from the loaded
case through to the floor. Placing shims
at other locations will cause uneven
distribution of weight leading to piping
leaks, as well as sagging or wracked
doors.
5-Door Island Shown
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
Skid/External Base
Electrical Wireway
Approximately
Centered
Rear of Reach-in
Base
Component
Shim Here
Shim
Here
Bottom Front
Support
Base Component
Shim Here
NO SHIM
HERE
Electrical Wireway
Reach-In
1-3