Serial Plate Information; Start-Up Procedure - Hussmann HGL-1BS Installation And Service Instructions Manual

Bottom & top mount remotes
Hide thumbs Also See for HGL-1BS:
Table of Contents

Advertisement

NOTE: Connecting this unit to any elec-
trical supply other than specified on the
serial plate will VOID the warranty and
may result in serious damage to the unit.
The cabinet should be supplied with its
own service.
SERIAL PLATE INFORMATION –
The serial plate is located in the
upper left hand corner of the case inte-
rior. It has all the pertinent information
needed for proper electrical installation.
The serial plate should not be removed
for any reason.
START UP PROCEDURE -
After the wiring has been completed,
set the defrost timer for the correct
time of day, making sure the defrost
pins are secure in the face of the
clock. HGL cabinets are factory set
for 2 defrost periods in 24 hours. (6
a.m. and 10 p.m.)
Check the cabinet thoroughly for
loose nuts and bolts and electrical
connections. Inspect the refrigera-
tion lines for any visible damage or
chafing.
Replace the electrical box cover.
Start the cabinet and allow to pull
down to operating temperature be-
fore loading.
BTU CAPACITIES -
BTU/HR
1-T/B
3100
2-T/B
4160
3-T/B
5900
ELECTRICAL SPECIFICATIONS
HZ/PH VOLTS
1-T
60/1
208-230
2-T
60/1
208-230
3-T
60/1
208-230
1-B
60/1
208-230
2-B
60/1
208-230
3-B
60/1
208-230
All cases use R-404A refrigerant. Please
check the serial plate for the specific re-
frigerant used.
Page 7
RATING TEMP ºF
EVAP
COND
AMB
-20
110
90
-20
110
90
-20
110
90
RUN
AMPS FUSE
WT.
7.9
15AMP
547
8.8
15AMP
755
11.0
15AMP
986
7.9
15AMP
547
8.8
15AMP
816
11.0
15AMP
1065