Important Steps; Case Cleaning; Maintenance; Replacing Fluorescent Lamps - Hussmann CRFD Installation And Operation Manual

Floral case
Hide thumbs Also See for CRFD:
Table of Contents

Advertisement

Rev. 0508
5. When stocking, never allow the product to extend
beyond the recommended load limit. Air discharge
and return air flue must be unobstructed at all
times to provide proper refrigeration.
6. Do not place any signs or other restrictive
objects on the front of the refrigerator that will
block the air intake vents.
7. Avoid the use of supplemental flood or spot lighting.
Display light intensity has been designed for
maximum visibility and product life at the factory.
The use of higher output fluorescent lamps (H.O.
and V.H.O.), will shorten the shelf life of the product.
8. Cold coils remove heat and moisture from the
case and deposit this as frost onto the coil. Thus, a
defrost is required.

Important steps

1. Do not set temperature too cold, as this causes
product dehydration.

Case Cleaning

Long life and satisfactory performance of any equipment
are dependent upon the care given to it. To insure long
life, proper sanitation and minimum maintenance costs,
the refrigerator should be thoroughly cleaned frequently.
SHUT OFF FAN DURING CLEANING PROCESS. It can be
unplugged within the case, or shut off case at the source.
The interior bottom may be cleaned with any domestic soap
or detergent based cleaners. Sanitizing solutions will not
harm the interior bottom, however, these solutions should
always be used according to the manufacturer's directions.
It is essential to establish and regulate cleaning procedures.
This will minimize bacteria causing discoloration which
leads to degraded product appearance and significantly
shortening product shelf life.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heaters
Thermostats, and Lights.

Replacing Fluorescent Lamps

Fluorescent lamps are furnished with a shatterproof
protective coating. The same type of lamp with protective
coating must be used if replaced.
User Information (Cont'd)
Soap and hot water are not enough to kill this bacteria. A
sanitizing solution must be included with each cleaning
process to eliminate this bacteria.
1. Scrub thoroughly, cleaning all surfaces, with soap
and hot water.
2. Rinse with hot water, but do not flood.
3. Apply the sanitizing solution according to the
manufacturer's directions.
4. Rinse thoroughly.
5. Dry completely before resuming operation.
When cleaning:
• Do not use high pressure water hoses
• Do not introduce water faster than waste outlet can drain
• NEVER ON A SELF CONTAINED UNIT WITH AN EVAPORATOR FAN
• NEVER USE A CLEANING OR SANITIZING SOLUTION THAT HAS AN OIL
BASE (these will dissolve the butyl sealants) or an AMMONIA BASE
TO PRESERVE THE ATTRACTIVE FINISH:
• DO USE WATER AND A MILD DETERGENT FOR THE EXTERIOR ONLY
• DO NOT USE ABRASIVES OR STEEL WOOL SCOURING PADS
(these will mar the finish)

Maintenance

This lamp has been treated to resist breakage and must be
replaced with a similarly treated lamp in order to maintain
compliance with NSF Standards.

evaporator Fans

The evaporator fans are located at the center front of these
merchandisers directly behind the front wall at the center of
the display. Should fans or blades need servicing, always
replace fan blades with the raised embossed side of the
blade TOWARD THE MOTOR.

Copper Coils

The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.
7
CLEANING PRECAUTIONS
(this will corrode the copper componets of the case)
Contact HUSSMANN Chino for replacement
1-800-395-9229 x 2131
NSF CODE 4.28.1