LEDs on the Cisco MDS 9200 Series Integrated Supervisor Modules

Table 1-1
Table 1-1
LED
Status
Speed
Link
1. The Speed LEDs are available only on Cisco MDS 9216i and Cisco MDS 9216A Supervisor
Cisco MDS 9200 Series Hardware Installation Guide
1-8
describes the LEDs for the Cisco MDS 9200 Series integrated supervisor modules.
LEDs for the Cisco MDS 9200 Series Integrated Supervisor Modules
Status
Description
Green
All diagnostics pass. The module is operational (normal
initialization sequence).
Orange
One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product
life, you should immediately correct the
environmental temperature and restore the system to
normal operation.
Red
One of the following occurred:
The diagnostic test failed. The module is not
operational because a fault occurred during the
initialization sequence.
T
safe operating temperature limits of the card (a major
environmental warning). The card shut down to
prevent permanent damage. The system will be shut
down after two minutes if this condition is not cleared.
1
On
2/4-Gbps mode.
Off
1-Gbps mode.
Solid green Link is up.
Flashing
Link is up (beacon used to identify port).
green
Solid
Link is disabled by software.
yellow
Flashing
A fault condition exists.
yellow
Off
No link.
Modules.
he inlet air temperature of the system exceeded the
Chapter 1
Product Overview
OL-19588-01