Assembly Instructions; Features; Control Panel - Schumacher SEM-1562A-CA Owner's Manual

Automatic battery charger
Table of Contents

Advertisement

8.3 USING AN EXTENSION CORD
The use of an extension cord is not recommended. If you must use an extension
cord, follow these guidelines:
• Pins on plug of extension cord must be the same number, size, and shape as
those of plug on charger.
• Ensure that the extension cord is properly wired and in good electrical condition.
• Wire size must be large enough for the AC ampere rating of charger, as specified:
Length of cord (feet)
AWG* size of cord
*AWG-American Wire Gauge
9.

ASSEMBLY INSTRUCTIONS

9.1 Remove all cord wraps and uncoil the cables prior to using the battery charger.

10. FEATURES

2

11. CONTROL PANEL

LED DISPLAY
CLAMPS REVERSED (red) LED flashing: The connections are reversed.
CHARGING (yellow/orange) LED lit: The charger is charging the battery.
CHARGING (yellow/orange) LED flashing: The charger is in abort mode.
CHARGED (green) LED pulsing: The battery is fully charged and the
charger is in maintain mode.
NOTE: See Operating Instructions for a complete description of the charger modes.
25
50
18
18
1
3
• 7 •
100
150
18
16
1.
Ring connectors (quick-connect)
2.
Battery clamps (quick-connect)
3.
Battery status LEDs

Advertisement

Table of Contents
loading

Table of Contents