IMPORTANT!
This cooktop must be connected to the mains power supply only by a suitably qualified
●
person.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
●
branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
●
temperature will not exceed 75
o
C at any point.
Before connecting the cooktop to the mains power supply check that:
The domestic wiring system is suitable for the power drawn by the cooktop.
●
The voltage corresponds to the value given in the rating plate
●
The power supply cable sections can withstand the load specified on the rating plate.
●
Power supply
CI302DTB3
3700W@ 220-240V 1N ~ 16A*
CI603DTB2
6950W@ 220-240/380-415V 2N ~ 30A
CI604DTB3
7000W @ 220-240/380-415V 2N ~ 30A
CI754DTB2
7400W @ 220-240/380-415V 2N ~ 32A
CI905DTB2
9800W @ 220-240/380-415V 3N ~ 43A
CI905DTB3
11100W @ 220-240/380-415V 3N ~ 48A
*The CI302DTB2 comes supplied with a cable. This must be wired into a suitably rated plug,
permanent connection outlet or power isolator.
IMPORTANT!
Check with an electrician whether the domestic wiring system is suitable without alterations.
Any alterations must only be made by a qualified electrician.
!1
FIT CLAMPING BRACKETS BASED ON THE
BENCHTOP THICKNESS
No. of brackets and slot positions depends on model
view from below
12-40mm
!0
CONNECTING THE COOKTOP TO THE MAINS POWER SUPPLY
Fit a minimum of
2 brackets on opposing sides
40mm+
Connection diagrams
CI302DTB3, CI603DTB2, CI604DTB3, CI754DTB2
Single-phase connection
220-240V~
2
4
1
3
5
L
N
PE
CI905DTB2, CI905DTB3
Single-phase connection
220-240V~
2
4
1
3
5
L
N
PE
!2
SECURE TO BENCHTOP
Two-phase connection
380-415V 2N~
2
4
1
3
5
L
L
N
PE
1
2
Three-phase connection
380-415V 3N~
2
4
1
3
5
N
PE
L
L
L
1
2
3
Secure on at least 2
opposing sides
Repeat on all the other brackets
9