Download Print this page

TecMate Optimate TM274 Instructions For Use Manual page 8

Automatic charger for 12.8v lifepo4 batteries
Hide thumbs Also See for Optimate TM274:

Advertisement

STEP 7
LED #4 : YELLOW
CHARGE
5
4
3
STEP 8
LED #5 : YELLOW
8
OPTIMIZE
5
4
STEP 9
LED #6
TEST after
charge
8
5
STEP 10
LED #6 / 7 / 8
OptiMATE
smart
6
MAINTAIN
7
TEST
For batteries with a
good state of health
LED #6 (green) will
remain on.
NOTES ON TEST RESULTS:
1. For any test result other than green #6, disconnect the battery from the electrical system it supports, and
reconnect the OptiMate. If a better test result is now obtained, this suggests that the power losses are partly due
to an electrical problem in the electrical system and not in the battery itself.
NOTE: A sudden load being switched on while the charger is connected can cause the battery voltage to
reduce significantly and test result to worsen.
2. TEST LED #8 (red) flashing - Charging is suspended.
If it occured during -
8
Within the normal safeTº temperature zone the ampmatic™
TEST
LiFePO
4
rate of charge current for the connected battery, according to its state
of charge, state of health, and electrical storage (Ah) capacity. The
delivered current may be anywhere from 1.25A to 9.5A for batteries
with an electrical storage (Ah) capacity less than 10Ah (8Ah) charge
current is automatically adjusted lower to an average equal to battery
Ah capacity, e.g. a 2.5Ah / 2500mAh battery receive an average of 2.5
Amps.
NOTE: For safety reasons there is an overall charge time limit of 24
hours for SAVE and CHARGE modes.
The OPTIMIZE mode starts when the voltage has reached 14.4V for
the first time during bulk CHARGE mode.
The ampmatic™ current control program now delivers pulses of
TEST
current to equalise the individual cells within the battery and optimizes
charge level.
Charging should complete within the minimum charge time set during
STEP 3, but if the battery requires further charging the program will
extend OPTIMIZE mode up to a maximum of 2 hours.
FLASHING
TEST after charge : Delivery of current to the battery is interrupted
for 30 minutes* to allow the program to determine the battery's
* IF charging started in SAVE mode (LED #3, indicating a deep
6
discharged battery) the voltage retention test is extended to 12
7
The TEST result (indicated on LED # 6, 7, 8) is adjusted in real time
TEST
according to the measured battery voltage. Consult the "EARLY
WARNING OF BATTERY PROBLEMS" table on page 2 to match TEST
LED indication to an estimated state of charge percentage (SOC%).
More information is provided in the section "NOTES ON TEST
RESULTS".
ON
according to final voltage measured at termination of STEP 9.
The MAINTENANCE CHARGE CYCLE consists of 30 minute charge
periods followed by and alternating with a 30 minute 'rest' periods,
during which there is no charge current.
During the 30 minute charge cycles current is delivered only if the
battery has lost charge.
The BATTERY REFRESH CYCLE is performed if the charger detects the
battery has lost significant charge. The program returns to OPTIMIZE
mode (LED #5) and then proceeds to the voltage retention test and
maintenance charge cycle.
Read section MAINTAINING A LITHIUM BATTERY FOR EXTENDED
PERIODS.
specific program automatically determines the most efficient
ability to retain charge.
hours to confirm battery health.
MAINTENANCE CHARGE: LED #6 / 7 / 8 steady on

Advertisement

loading

This manual is also suitable for:

Optimate tm275Optimate m276Optimate tm278