6. To remove high voltage capacitor.
(1) Remove a screws 1 which secure the
grounding ring terminal of the H.V. diode 2
and the capacitor holder 3.
(2) Remove the H.V. diode 2 from the capaci-
tor holder 3.
(3) Remove the above steps for reassembly.
High voltage circuit wiring
H.V. Transformer
7. To remove magnetron.
(1) Remove three screws 1 which secure the
magnetron 2.
(2) Remove the magnetron 2 .
(3) Reverse the above steps for reassembly.
Magnetron
H.V. Capacitor
H.V. Diode
30
1
3
2
2
1