Note: To remove cubes on the Evaporator, turn off the power supply and
turn it on after 3 minutes. The defrost cycle starts and the cubes
will be removed from the Evaporator.
3) Turn off the power supply.
4) Remove the Front Panel, and then remove the Insulation Panel by first lifting the Top
Panel and sliding the Top Panel to the back a little.
5) Remove the Rubber Cap covering the Overflow Pipe in the Water Tank. Remove the
Overflow Pipe by turning it counterclockwise. Drain the Water Tank. See Fig. 11.
6) Replace the Overflow Pipe and the Rubber Cap in their correct position.
7) Pour the cleaning solution into the Water Tank.
8) Fully open the Cleaning Valve on the left side wall of the machine compartment.
9) Move the Control Switch, on the Control Box, to the "WASH" position
10) Replace the Insulation Panel and the Front Panel in their correct position.
Note: When replacing the Insulation Panel, do not catch the Hose
between the panel and the body.
11) Turn on the power supply, and start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the Front Panel, and then remove the Insulation Panel by first lifting the Top
Panel and sliding the Top Panel to the back a little.
14) Remove the Rubber Cap covering the Overflow Pipe in the Water Tank. Remove the
Overflow Pipe by turning it counterclockwise. Drain the Water Tank. Replace the Over-
flow Pipe, the Rubber Cap and the Insulation Panel in their correct position.
15) Move the Control Switch to the "ICE" position.
16) Close the Cleaning Valve.
17) Replace the Front Panel in its correct position.
18) Turn on the power supply to fill the Water Tank with water.
19) Turn off the power supply after 3 minutes.