7.
Disconnect the water valve's outlet water line to the
reservoir and drain the remaining water left in the
water line trap area.
To disconnect the water
outlet line: Push up on the
white collar and pull the plastic
water line from the bottom of the
water valve.
To reconnect the water
outlet line: Simply insert the
plastic tubing into the white collar
and push until it stops (about
12 mm, of water line will enter
the valve).
8.
Reconnect the water valve outlet water line.
9.
Reinstall the ice machine's access cover.
10. Clean and dry the ice machine's storage bin.
11. Prop the door open for air circulation to prevent mold
and mildew.
12. Leave the water supply line disconnected or reconnect
the supply line and leave it shut off. Do NOT turn the
water on and allow water to enter back into the water
valve.
13. Install the winterization plug in the water drain hole
inside the ice bin.
Extended Non-Use
White
",
1
2
collar
Plastic outlet
water line
Winterization
plug
14. Remove the top clamp from the vent tube, for easy
access to the air hose.
15. Apply air pressure (approximately 10 psi) to the end
of he vent tube which will purge the remainder of the
water from the drain pump and the drain line.
16. Reinstall the vent tube and clamp to the back of the
ice machine and remove the winterization plug from
the ice bin and save it for future use.
27
u-line.com
Vent
Remove
tube
clamp
screw
Drain
line