Texas Instruments AMC7823 EVM User Manual page 12

Evaluation module
Table of Contents

Advertisement

EVM Operation
Reference
Jumper Setting
1
W2
1
1
W3
1
1
W4
1
W5
1
W6
1
1
W7
1
1
1
W8
1
1
W9
1
12
AMC7823 Evaluation Module
Table 3. Jumper Settings and Functions (continued)
3
+5-V analog supply is selected for DUT IOV
3
+3.3-V analog supply is selected for DUT IOV
3
+5-V analog supply is selected for DUT AV
3
+3.3-V analog supply is selected for DUT AV
3
+5-V digital supply is selected for DUT DV
3
+3.3-V digital supply is selected for DUT DV
Signal ground is not connected to analog ground. Use this for differential input signal application.
Signal ground is connected to analog ground. Use this for single-ended input signal application.
3
CS signal from J2-1 is routed through to control the SS function of the AMC7823. Normally used
for µC operation.
3
FSX signal from J2-7 is routed through to control the SS function of the AMC7823. Normally used
for DSP operation.
3
External reference input voltage via REF1 is routed to W1 pin 3.
3
External reference input voltage via REF2 is routed to W1 pin 3.
3
TOUT signal is used to generate the external trigger for ADC conversion.
3
Internal trigger for conversion is used.
3
BCLK or LRCLK signal, as selected by W9, is used to generate the external trigger for ADC
conversion.
3
BCLK signal from J4-3 is routed through to generate the external trigger for ADC conversion.
Normally used for µC operation.
3
LRCLK signal from J4-7 is routed through to generate the external trigger for ADC conversion.
Normally used for µC operation.