1.11.3 Replacing the ATO board, ATO pump relay or Transformers
Disconnect the fryer from the electrical power
supply. Locate the ATO box (see Figure 1 on page
12), behind the JIB (Jug In Box). Remove the cover
to expose the transformers and relay (see Figure 2).
Mark and unplug any wires or harnesses. Replace
the defective component and reattach all wires or
harnesses.
Replace the cover. Once replaced,
CYCLE
POWER
TO
SYSTEM. See section 1.12.6 on page 1-23 to reset
control power. Check software version and if
necessary update the software. If a software update
was necessary, follow the instructions to update the
software in section 1.16.
Press the temperature button on one of the FilterQuick
verify software version of the ATO. If the version is not visible, the ATO may not be connected properly.

1.11.4 Replacing the ATO Pump or Solenoid

Disconnect the fryer from the electrical power
supply. Locate the ATO pump (see Figure 4), behind
the ATO box. Mark and unplug any wires or
harnesses. Press up from the bottom on the quick
disconnects to release the plumbing (see Figure 5).
The plumbing can be pulled from the pump. Loosen
the four nuts attaching the pump to the pump tray.
Replace the defective component and reverse above
steps. Once replaced, reconnect the power

1.12 MIB (Manual Interface Board) Service Procedures

The MIB (Manual Interface Board) oversees and controls filtration. It receives and sends data over the CAN
(Controller Area Network) to and from various sensors and controllers. It activates the filtration cycle,
controlling when actuators should open and close.
The MIB controller is located inside the left cabinet (see Figure 6). In normal operation a cover hides the MIB
controls and only the LED display is visible. The cover is held in place with three torx screws. In normal
operation, an "A" is displayed for automatic mode. The MIB control board is useful for diagnostic purposes. It
allows manual operation of both the actuators and filter pump without using the controller.
Figure 6: MIB controller cover.
ENTIRE
FRYER
controllers, with the controller in the OFF position, to
.
Mode Display
Vat Selector
Switch
Manual /Auto
Switch
Figure 7
1-18
Figure 2
Figure 4
Figure 5
Reset Switch
Drain Switch
Return Switch